Haier AD072XLEAA [78/89] Open alarm state

Haier AD072XLEAA [78/89] Open alarm state
3 Pressure protection
4 discharge temperature is over
-
high
5 compressor doesn
t run
Check the
magnetic
contactor
is good or not
D
isconn
ect compressor to
check the system can work for
short time or not
C
ompressor doesn
t run
Use multi-meter to test
the pressure swit
ch.
S
hort
-
connected: OK
Open: alarm state
P
ressure switch alarm
A
bnormal
C
heck the wires connection
OK
Run the system, check the
true pressure is good
P
ressure is abnormal
Check the valve state, pipes
are deformed , leaking or not,
refrigeration cha
rging
C
hange outdoor PCB
OK
Discharge temp. is
over high
T
est the true temp. . if
the temp. is really
very high
Check the refrigeration charging,
pipe system is deformed, leaking or
blocked or not
if the temp. is not
very high
C
hange sensor
Check the indoor controller
setting is right or not
Chff^j\bZe Abj Chg]blbhg^j
z 76 z