Cautions
Temperature and Humidity Range
If the air conditioner is used under higher
temperature condition than those listed,
the built-in protection circuit may operate
to prevent internal circuit damage. Also,
during Cooling and Dry modes, if the unit
is used under conditions of lower
temperature than those listed above, the
heat-exchanger may freeze, leading to
water leakage and other damage.
Do not use this unit for any other purposes
except for the Cooling and the Heating,
Dehumidifying, and air-circulation of
rooms should be in ordinary dwellings.
The wiring method should be in line with
the local wiring standand.
The waste battery should be disposed
properly.
If the fuse on PC board is broken, please
change it with the type T 3.15A/250VAC.
The air breaker should be all-pole switch.
and the distance between it's two contacts
should no less than 3mm.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -15
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
*.ERA :
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
*.EAA :
For this model, the all-pole discon-rexion
connection method should be applied in
the power supply.
Such means for disconnection must be
incorporation in the fixed wiring.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
Содержание
- Convertible type air conditioner 1
- Operation installation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Caution 5
- Danger 5
- Safety precautions 5
- Warning 5
- Fig indoor unit 6
- Name of parts 6
- Caution 7
- Cleaning and care 7
- Cleaning the air filter 7
- Mark parts name 8
- Operation tips 8
- Standard parts 8
- Caution 9
- Installation 9
- Location 9
- Operating noise 9
- Warning 9
- Wiring 9
- Installation procedures 10
- Under ceiling 10
- Warning 10
- A floor console type 11
- Drilling for piping 11
- Installation procedures 11
- Preparing indoor unit installation 11
- Remove the intake grill 11
- B under ceiling type 12
- Drain hose 12
- Drain pan 12
- Installation procedures 12
- Installing drain hose 12
- Insulation drain hose 12
- Nylon fastener 12
- Ok no no 12
- Using the installation template drill holes for piping and anchor bolts for holes fig 0 12
- Caution 13
- Drilling for piping 13
- Drilling holes for anchor bolts and installing the anchor bolts 13
- Fig 16 13
- Fig 17 13
- Hex bolt 13
- Installation procedures 13
- Installing brackets 13
- To 13mm indoor unit 13
- Connecting the piping 14
- Fig 18 14
- Fig 19 14
- Fig 20 14
- Fig 21 14
- Installation procedures 14
- Outdoor unit installation 14
- A for solid core wiring or f cable fig 4a 15
- B for strand wiring fig 4b 15
- Fig 25 insulation tube 15
- How to connect wiring to the terminals 15
- How to fixed connection cord and power cable at the cord clamp 15
- Installation procedures 15
- 1 match the terminal block numbers and connection cord colors with those of the outdoor unit erroneous wiring may cause burning of the electric parts 16
- 2 connect the connection cords firmly to the terminal block imperfect installation may cause a fire 16
- 3 always fasten the outside covering of the connection cord with the cord clamp if the insulator is chafed electric leakage may occur 16
- 4 always connect the ground wire 16
- Caution 16
- Connection cord m 16
- Electric component box 16
- Electrical requirement 16
- Electrical wiring 16
- For series 142 for series 182 for series 242 16
- Indoor unit side 16
- Installation procedures 16
- Power supply 16
- Power supply 1ph 220 230v 50hz 16
- Remove the four tapping screws 16
- Caution 17
- Installation procedures 17
- Mount the cover plate and the intake grill 17
- Test running 17
- Fig 34 18
- Fig 35 18
- Installation procedures 18
- Mount the intake grill 18
- Followings are not problems 19
- Trouble shooting 19
- Air conditioner won t start 20
- Before ask for services please first check your unit against the following 20
- Poor cooling 20
- Poor cooling or heating 20
- Trouble shooting 20
- Error display for era 21
- Trouble shooting 21
- Error display for eaa 22
- Trouble shooting 22
Похожие устройства
- Haier AC142ACEAA Инструкция по эксплуатации
- Haier AB142ACBEA Инструкция по эксплуатации
- Haier AB182ACBEA Инструкция по эксплуатации
- Haier AB242ACBEA Инструкция по эксплуатации
- Haier AB28NACBEA Инструкция по эксплуатации
- Haier AB36NACBEA Инструкция по эксплуатации
- Haier AB42NACBEA Инструкция по эксплуатации
- Haier AB52NACBEA Инструкция по эксплуатации
- Haier AD422BMBAA Инструкция по эксплуатации
- Haier AC28ES1ERA Инструкция по эксплуатации
- Haier AC36ES1ERA Инструкция по эксплуатации
- Haier AC48FS1ERA Инструкция по эксплуатации
- Haier AC60FS1ERA Инструкция по эксплуатации
- Haier AC142ACEEA Инструкция по эксплуатации
- Haier AC182ACEEA Инструкция по эксплуатации
- Haier AC242ACEEA Инструкция по эксплуатации
- Haier AU122ACARA Инструкция по эксплуатации
- Haier AB094FAAHA Инструкция по эксплуатации
- Haier AB124FAAHA Инструкция по эксплуатации
- Haier AB184FCAHA Инструкция по эксплуатации