Haier AV28NMVERA [114/531] Ph 220 230v 50hz

Haier AV10NMVERA [114/531] Ph 220 230v 50hz
5. Wiring diagrams
137
2
1
3
G
CN20
22
CN1
5
5
CN3
2
1
3
3
1
2
234
1
2
34
1
C
AC12.5V
AB
CN23
1
1
2
1
1
2
1
23
1
23
CN22
7
7
L
N
TR
2. is printed circuit board
1. is terminal block, the words on it
3.The Parts in the dashed frame are optional
in accordance with the reality of the manufacture.
Transmission Lamp between
Forced-open lamp for indoor
Malfunction lamp for I.D unit
Transmission Lamp between
I.D and O.D unit
LED
LED1
LED4
LED3
LED5
LED6
LED2
R
G
R
R
Y
G
Electronic Expansion Valve
Wired remote controller and I.D Unit
Fan speed controller
Fusion
Temperature switch
Electric heater
Swing
Pump Motor
Float Switch
Terminal block (Control)
Terminal block (Power)
Running Capacitor
Fan Motor
Ambient Temperature Sensor
Gas Pipe Temperature Sensor
Transformer
Electronic Expansion Valve
Symbol
Description
Liquid Pipe Temperature Sensor
Relay
CN13
RC
QO
2
1
2
1
21
21
CN16CN14
5
5
2
2
1
1
34
3
4
6
6
CN21
250VACT5A
1
2
12
CN31
CN26
2
1
2
1
CN11
3
45
345
2
2
1
1
1
2
1
2
CN34
CN33
1
1
2
2
543
543
6
6
6
6
3
45
3
452
2
1
1
SW01
SW08
SW07
SW02
SW03
LED4
LED3
LED6
CN30
10
LED2LED1
LED5
1
2
3
4
5
8
7
6
9
TR
TA
RC
FM
TC2
TC1
TW1
TW2
PS
PM
SM
RL
PMV
CN23
J19
CN21
CN30
TS
F
FC
EH
0010525047
RL
RL RL
Y/G
FM
RC
M
14
56
EH
EH
EH EH
F
TS TS
RL
PM
~
TW1
TW2
1
1
2
2
QP
CN15
CN9
2
2
6
6
3
45
345
1
1
3
2
32
1
1
1
2
CN6
2
1
CN5
2
11
2
CN4
2
1
2
1
CBA
CN24
RC
CN8
5
3
11
3
5
CN7
11
2
2
CN18
1
3
2
1
1
3
2
1
TC1
TC2
TA
CN19
2
1
3
1PH,220-230V,50Hz
TO POWER SUPPLY
Wired Remote Controller
(To O.D unit)
Wiring
Transmission
BLY
OR
GR
GR
G
B
B
R
BL W
Y/G
Y/G
BL
W
W
R
B
R
WR
R
R
BL
W
G
R
R
R
FUSE
PCB
W
W
W
W
W
R
G
Y
W
WIRING DIAGRAM OF INDOOR UNIT
Malfunction Code indication by Wired Remote Controller
Malfunction of O.D unit
improper setting SW02
Address duplication
0A
10
improper setting SW03
Address duplication
Malfunction of Drain
level control system
between I.D and O.D unit
Malfunction of transmission
of LED5 on the
The Flash Times
LED on the
the PCB/Timing
and I.D unit
between rmote Controller
source sensor failure
sensor TC2 failure
sensor TC1 failure
sensor TA failure
Code
2
1
Malfunction Contents
Indoor gas pipe temp.
Indoor ambient temp.
3
7
8
5
6
4
EEPROM failure
20
9
Indoor liquid pipe temp.
Malfunction of transmission
Indoor twin energy
Malfunction
03
07
09
08
04
06
05
02
01
Wireless Receiver
remote receiver
Connect to
Disconnected
Sho rt connecte d
Sh ort co nnect ed
Null
*Master/Slave Wired Remote controller and Wireless Remote Setting
At the time of installation or after service inspection/repair
make the local setting in accrodance with the following table
Controller
Controller
Wired Remote
Wired Remote
(Control)
Disconnected
Wired Controller
Wired C ontroller
/Jumper
Mod e
B.C co nnect with
Disconnected
Slave Remote
Master Remote
Null
A.B.C connect with
Terminal Block
Setting
Socket
A,B,C Null
Disconnected
Wireless Remote Controller
Shor t connec ted
Short connected
Sh ort co nnect ed
between I.D and O.D unit
Wired controller address and
capacity setting of indoor unit
SW03
SW01
Dip Switch Function
Dip switch (8HP)
Transmission address setting
Transmission address setting between I.D and central controller
Dip switch (8HP)
SW02
Dip switch (8HP)
are the sequence number