Haier AB092FCAIA [6/11] Installation procedures
![Haier AB092FCBIA [6/11] Installation procedures](/views2/1821616/page6/bg6.png)
5
Indoor unit
Name of Each Part
Swing louver
(Air flow direction can be adjusted by using
the SWING button on the remote controller)
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Operating Control Panel
Electrical box
16
Piping Connection
(1) Dimension of connecting pipe
Fit the nut on and fasten
(2) The maximum length and drop height of connecting pipe
The maximum length is 20m
The maximum drop height is 10m.
To ensure the efficiency ,Pipes shall be as short as possible.
Cautions for piping connection
Do not twist or deform the connecting pipe.
Do not mix dusts.
The bending radius shall be as large as possible.
Both gas pipe and liquid pipe shall be heat insulation.
No leakage in the flare.
(3) Piping connection
Connecting method
Smear refrigerant oil on the joints of piping and flare.
The bending radius shall be as large as possible.
Align the pipe center when fastening, and tighten the
nut, as shown in the figure.
Pay attention to not mix foreign matters such as sands
in.
Diameter of Pipe
Liquid Pipe 6.35mm
Gas Pipe 12.7mm
Tighten Torque
(N. m)
11.8
49.0
If not aligned ,tighten the nut by force will
damage the nut that result in gas leakage
12.7mm
6.35mm
Gas pipe
Liquid pipe
Spanner
Spanner
Joint
Nut
Installation Procedures
Содержание
- Cassette type air conditioner 1
- Contents 1
- Indoor unit operation installation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Cautions 3
- Installation procedures check and test run 3
- Other instructions 3
- Specifications 3
- If fan speed in auto mode it will automatically lower when the room temperature close to the setting temperature in cooling mode 4
- If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine 4
- In dry mode fan speed will be automatically varied 4
- In heating mode the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops 4
- Main points of operation 4
- Minute protection function 4
- Operation of air conditioner 4
- Please check the following things about your air conditioner before making a service call 4
- Remote control 4
- There is a telecommunication interface for remote control on the control panel of the indoor unit after the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector the air conditioner will be computerized and controlled from a far away place 4
- Trouble shooting 4
- Unit fails to start 4
- Variation of fan speed 4
- When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 4
- Defrosting function 5
- In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off 5
- In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes during defrosting both indoor and outdoor fan will stop running when defrosting finished air condi tioner will automatically back to running 5
- Main points of operation 5
- Power failure compensation to be applied for a necessary situation 5
- Prevent cool air blowing off 5
- Remote controller units please press the remote controller botton code to choose the program of code b 5
- The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects 5
- The followings are not malfuncition 5
- Trouble shooting 5
- Air filter inside of the inlet grille 6
- Air inlet grille 6
- Electrical box 6
- Indoor unit 6
- Installation procedures 6
- Name of each part 6
- Operating control panel 6
- Piping connection 6
- Swing louver air flow direction can be adjusted by using the swing button on the remote controller 6
- Below are listed four kinds of safety cautions and suggestions 7
- Carefully read the following information in order to operate the air conditioner correctly 7
- Caution 7
- Install ornament panel on indoor unit 7
- Installation of ornament panel 7
- Installation procedures 7
- Instruction 7
- Limits of panel board installation 7
- Safety cautions 7
- Warning 7
- Cautions for the water drainage lifting pipe 8
- Installation of water drainage pipe 8
- Installation procedures 8
- Safety cautions 8
- Warning 8
- After installation on the ceiling 9
- Caution 9
- Clean indoor unit 9
- Clean the air filter 9
- Clean the unit 9
- In the case of ceiling already exists 9
- Installation of indoor unit 9
- Installation procedures 9
- Lug two corners of the filter at the same time pull off the filter 9
- Maintenance 9
- Installation preparation 10
- Installation procedures 10
- Maintenance 10
- Post season care 10
- Pre season care 10
- Seasonal reserve 10
- Selection of installation place 10
Похожие устройства
- Haier AB092FCAIA Сервис мануал
- Haier AB142FCAIA Инструкция по эксплуатации
- Haier AB142FCAIA Сервис мануал
- Haier AB182FCAIA Инструкция по эксплуатации
- Haier AB182FCAIA Сервис мануал
- Haier AC182FCAHA Сервис мануал
- Haier AE072FLAIA Сервис мануал
- Haier AE092FLAIA Сервис мануал
- Haier AE122FLAIA Сервис мануал
- Haier AE142FLAIA Сервис мануал
- Haier AE182FLAIA Сервис мануал
- Haier AE242FLAIA Сервис мануал
- Haier AE072FCAMA Сервис мануал
- Haier AE092FCAMA Сервис мануал
- Haier AE122FCAMA Сервис мануал
- Haier AE142FCAMA Сервис мануал
- Haier AE182FCAMA Сервис мануал
- Haier AE212FCAMA Сервис мануал
- Haier AE242FCAMA Сервис мануал
- Haier AS072FCAIA Сервис мануал