Haier AB092FCAIA [8/11] Installation procedures
![Haier AB092FCBIA [8/11] Installation procedures](/views2/1821616/page8/bg8.png)
7
WARNING
No goods or nobody is permitted
to be placed on or stand on
outdoor unit.
Donít clean air conditioner
with water.
Safety Cautions
The falling of goods and
people may cause accidents.
Don't operate the air conditioner with
damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other
materials replacing fuse,othe-
rwise may cause faults or fire
accidents.
Donít place any burning
unit in the airflow of air
conditioner,which may
cause incomplete
combustion
No inflammable spray fluid
should be permitted to be
placed or used near to air
conditioner,otherwise may
cause fire accident.
Air conditioner should be
cleaned only after power
supply is cut off to keep
from shock or hurt.
Otherwise may cause shock.
Connect earthing wire.
Earthing wire should not be
connected to the gas pipe,
water pipe,lightning rod or
phone line,incorrect earthing
may cause shock.
Use discharge pipe correctly to
ensure efficient discharge.
In correct pipe usage may cause water
leaking.
Air conditioner canít be be installed in
the environment with inflammable gases.
The inflammable gases near to air conditioner
may cause fire hazard.
Installed electrical-leaking circuit breaker.
When use the fumigating insecticide
donít operate air conditioner.
Otherwise the poisonous chemicals
may settle in air conditioner,
which harm the health of
chemical-allergic people.
It easily causes electrical shock without
circuit breaker.
Not permitted
when running
14
4. Installation of water drainage pipe
(1) Install water drainage pipe
Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size:
25mm; O.D.: 32mm )
Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming.
If downward slope of drainpipe cannot be made,lifting pipe shall be installed.
Keep a distance of 1-1.5m between suspending bolts, to make water hose straight.
Use the drainage hose and clip provided with unit.
Insert water pipe into water plug until it reaches the white tape.
Tighten the clip until head of the screw is less than 4mm from hose.
Wind the ddrainage hose to the clip using seal pad for heat insulation.
Insulate drainage hose in the room.
5. Cautions for the water drainage lifting pipe
Installation height of water drainage lifting pipe shall be less than 280mm
There should be a right angle with unit ,300mm from unit.
< Note >
The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear
excessive force.
If several water hoses join together, of as per following procedures.
Specifications of the selected drainage hoses shall meet the requirements for the unit running
Slope below 1/100
Connection drainage hose with a T-joint
100mm ¸over
slope over 1/100
1-1.5m
Clip
Tape(white)
Draingage hose
Large size seal pad
4mm below
(accessory)
Clip
Clip
Water drainage
lifting pipe
Suspending bracket
Drainage hose
280mm unter
500mm below
220mm
300mm below
1-1.5m
220
Drainage hose
75mm below
500mm below
Installation Procedures
Содержание
- Cassette type air conditioner 1
- Contents 1
- Indoor unit operation installation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Cautions 3
- Installation procedures check and test run 3
- Other instructions 3
- Specifications 3
- If fan speed in auto mode it will automatically lower when the room temperature close to the setting temperature in cooling mode 4
- If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine 4
- In dry mode fan speed will be automatically varied 4
- In heating mode the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops 4
- Main points of operation 4
- Minute protection function 4
- Operation of air conditioner 4
- Please check the following things about your air conditioner before making a service call 4
- Remote control 4
- There is a telecommunication interface for remote control on the control panel of the indoor unit after the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector the air conditioner will be computerized and controlled from a far away place 4
- Trouble shooting 4
- Unit fails to start 4
- Variation of fan speed 4
- When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 4
- Defrosting function 5
- In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off 5
- In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes during defrosting both indoor and outdoor fan will stop running when defrosting finished air condi tioner will automatically back to running 5
- Main points of operation 5
- Power failure compensation to be applied for a necessary situation 5
- Prevent cool air blowing off 5
- Remote controller units please press the remote controller botton code to choose the program of code b 5
- The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects 5
- The followings are not malfuncition 5
- Trouble shooting 5
- Air filter inside of the inlet grille 6
- Air inlet grille 6
- Electrical box 6
- Indoor unit 6
- Installation procedures 6
- Name of each part 6
- Operating control panel 6
- Piping connection 6
- Swing louver air flow direction can be adjusted by using the swing button on the remote controller 6
- Below are listed four kinds of safety cautions and suggestions 7
- Carefully read the following information in order to operate the air conditioner correctly 7
- Caution 7
- Install ornament panel on indoor unit 7
- Installation of ornament panel 7
- Installation procedures 7
- Instruction 7
- Limits of panel board installation 7
- Safety cautions 7
- Warning 7
- Cautions for the water drainage lifting pipe 8
- Installation of water drainage pipe 8
- Installation procedures 8
- Safety cautions 8
- Warning 8
- After installation on the ceiling 9
- Caution 9
- Clean indoor unit 9
- Clean the air filter 9
- Clean the unit 9
- In the case of ceiling already exists 9
- Installation of indoor unit 9
- Installation procedures 9
- Lug two corners of the filter at the same time pull off the filter 9
- Maintenance 9
- Installation preparation 10
- Installation procedures 10
- Maintenance 10
- Post season care 10
- Pre season care 10
- Seasonal reserve 10
- Selection of installation place 10
Похожие устройства
- Haier AB092FCAIA Сервис мануал
- Haier AB142FCAIA Инструкция по эксплуатации
- Haier AB142FCAIA Сервис мануал
- Haier AB182FCAIA Инструкция по эксплуатации
- Haier AB182FCAIA Сервис мануал
- Haier AC182FCAHA Сервис мануал
- Haier AE072FLAIA Сервис мануал
- Haier AE092FLAIA Сервис мануал
- Haier AE122FLAIA Сервис мануал
- Haier AE142FLAIA Сервис мануал
- Haier AE182FLAIA Сервис мануал
- Haier AE242FLAIA Сервис мануал
- Haier AE072FCAMA Сервис мануал
- Haier AE092FCAMA Сервис мануал
- Haier AE122FCAMA Сервис мануал
- Haier AE142FCAMA Сервис мануал
- Haier AE182FCAMA Сервис мануал
- Haier AE212FCAMA Сервис мануал
- Haier AE242FCAMA Сервис мануал
- Haier AS072FCAIA Сервис мануал