Seasonal Reserve
Operate the unit with FAN mode on a fair day for about half
a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch .Electric
power is consumed even the air conditioner is in stop.
Clean the air filter, indoor unit and outdoor unit,and cover
the unit with dustcoat.
Pre-season Care
See that there is no obstacle blocking the air
inlet and air outlet of both indoor and outdoor
unit to avoid reduce the working efficiency.
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in
machine damages or cause malfunciton due th dust inside the unit
To protect compressor when start in HEAT mode,
please cut in the power supply switch 12 hours
before starting run,furthermore, always keep the
power supply switch on during the using senson.
Post-season Care
Maintenance
12
1.Selection of Installation Place
(1) Place above the ceiling where have enough space to arrange the unit.
(2) Place where the drainage pipe can be arranged well.
(3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked.
(4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).
(5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent
gas (thinner and gasoline) concentrates and retains.
(6) Place strong enough to support the unit weight.
(7) No expensive articles such as television and piano below indoor unit.
(8) Enough space for maintenance.
(9) Place more than 1m away from television and radio to avoid disturbing television and radio.
(10) Easy for maintenance.
2.Installation Preparation
(1) Position of ceiling opening between unit and suspending bolt (front view of unit).
(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller,
indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit
immediately after installation.
Overlap between ceiling and
ornament panel shall be 25mm
Suspending bolts
Ceiling
Ornament panel
150mm
320mm
60mm
Air outlet
Air outlet
Air inlet
2.5m Over (do not exceed 2.7m)
Distance between
suspending bolts 535mm
Indoor unit 570mm
Ceiling opening 650mm
Ornament panel 700mm
Indoor unit 570mm
Ceiling opening 650mm
Ornament panel 700mm
Installation Procedures
1.5m
1.5m
0.31m
H
Содержание
- Cassette type air conditioner 1
- Contents 1
- Indoor unit operation installation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Cautions 3
- Installation procedures check and test run 3
- Other instructions 3
- Specifications 3
- If fan speed in auto mode it will automatically lower when the room temperature close to the setting temperature in cooling mode 4
- If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine 4
- In dry mode fan speed will be automatically varied 4
- In heating mode the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops 4
- Main points of operation 4
- Minute protection function 4
- Operation of air conditioner 4
- Please check the following things about your air conditioner before making a service call 4
- Remote control 4
- There is a telecommunication interface for remote control on the control panel of the indoor unit after the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector the air conditioner will be computerized and controlled from a far away place 4
- Trouble shooting 4
- Unit fails to start 4
- Variation of fan speed 4
- When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 4
- Defrosting function 5
- In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off 5
- In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes during defrosting both indoor and outdoor fan will stop running when defrosting finished air condi tioner will automatically back to running 5
- Main points of operation 5
- Power failure compensation to be applied for a necessary situation 5
- Prevent cool air blowing off 5
- Remote controller units please press the remote controller botton code to choose the program of code b 5
- The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects 5
- The followings are not malfuncition 5
- Trouble shooting 5
- Air filter inside of the inlet grille 6
- Air inlet grille 6
- Electrical box 6
- Indoor unit 6
- Installation procedures 6
- Name of each part 6
- Operating control panel 6
- Piping connection 6
- Swing louver air flow direction can be adjusted by using the swing button on the remote controller 6
- Below are listed four kinds of safety cautions and suggestions 7
- Carefully read the following information in order to operate the air conditioner correctly 7
- Caution 7
- Install ornament panel on indoor unit 7
- Installation of ornament panel 7
- Installation procedures 7
- Instruction 7
- Limits of panel board installation 7
- Safety cautions 7
- Warning 7
- Cautions for the water drainage lifting pipe 8
- Installation of water drainage pipe 8
- Installation procedures 8
- Safety cautions 8
- Warning 8
- After installation on the ceiling 9
- Caution 9
- Clean indoor unit 9
- Clean the air filter 9
- Clean the unit 9
- In the case of ceiling already exists 9
- Installation of indoor unit 9
- Installation procedures 9
- Lug two corners of the filter at the same time pull off the filter 9
- Maintenance 9
- Installation preparation 10
- Installation procedures 10
- Maintenance 10
- Post season care 10
- Pre season care 10
- Seasonal reserve 10
- Selection of installation place 10
Похожие устройства
- Haier AB182FCAIA Сервис мануал
- Haier AC182FCAHA Сервис мануал
- Haier AE072FLAIA Сервис мануал
- Haier AE092FLAIA Сервис мануал
- Haier AE122FLAIA Сервис мануал
- Haier AE142FLAIA Сервис мануал
- Haier AE182FLAIA Сервис мануал
- Haier AE242FLAIA Сервис мануал
- Haier AE072FCAMA Сервис мануал
- Haier AE092FCAMA Сервис мануал
- Haier AE122FCAMA Сервис мануал
- Haier AE142FCAMA Сервис мануал
- Haier AE182FCAMA Сервис мануал
- Haier AE212FCAMA Сервис мануал
- Haier AE242FCAMA Сервис мануал
- Haier AS072FCAIA Сервис мануал
- Haier AS092FCAIA Сервис мануал
- Haier AS122FCAIA Сервис мануал
- Haier AS142FCAIA Сервис мануал
- Haier AS182FTAHA Сервис мануал