Haier AB182FCAIA [3/11] Cautions
![Haier AB092FCBIA [3/11] Cautions](/views2/1821616/page3/bg3.png)
2
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken please
change it with the type of T3.15A /250VAC.
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 21 -15
6 15 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
2
2
19
Other Instructions
1.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes
wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.
A leakage breaker must be installed.
Parameters of power supply: H07RN-F 3G 2.0mm
2
Connection method is Y-connection .If the power cord is damaged, it must be replaced by
professional people of manufacturer or its maintenance department or similar to avoid dangers.
2.Pipe cutting and expanding
Must remove burrs if cut pipes with pipe cutter.
Expand flare after insert the pipe expander.
Installation check and test run
Require customers to use air conditioner according to the operation manual.
The items checked during test run,please mark in
No gas leakage on the pipe joint ?
How about the thermal insulation of the pipe joint:
Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly?
Is the wiring of indoor and outdoor unit secured firmly?
Is the drainage hose arranged correct?
Is the earthing wire connected firmly?
Is the power supply voltage conformed to the electrical regulation?
Any noise?
Is the display on the control board (LCD) correct?
Cooling normal?
Does the indoor temperature regulator work normally?
For the power supply
L shall be connected to the live wire.
N shall be connected to the neutral wire.
Shall be connected to the earth wire.
The person who has completed this installation shall be requested to conduct a test operation for check:
Is the temperature adjuster working normally?
Does the location for installation conform to requirements?
Winding up with Protective Plastic Tape
The connection pipes, drain pipe, and the connection wires
shall be wound up with PVC tape.
Notes: The connection pipes shall also be wound up with insulating
material to preserve the temperature. The airing direction shall be
from bottom to top.
Trial Operation
Correct
Incorrect
Deflection
Crack occurs
Broken
Incomplete
Over outward
A
Pipe expander
Liquid pipe
Gas pipe
Diameter of pipe
Dimension A (mm)
1.0~1.2
1.4~2.2
6.35mm (1/4î)
12.7mm (1/2î)
Installation Procedures,Check and Test Run
4. The wiring method should be in line with
the local wiring standard.
5. Use copper wire only. The connecting cable
should be H05RN-F 4G 0.75mm . The power
cable should be H05RN-F 3G 2.5mm .
All the cables shall have got the European
authentication certificate.
6. The waste battery shall be disposed properly.
7. The indoor unit installation height is at least
2.5m.
8. The appliance must be installation that the
plug should be easily accessible after
installation.
9. The power plug should be self-provided and
it should have got the Local authenti-
cation certificate.
Содержание
- Cassette type air conditioner 1
- Contents 1
- Indoor unit operation installation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Cautions 3
- Installation procedures check and test run 3
- Other instructions 3
- Specifications 3
- If fan speed in auto mode it will automatically lower when the room temperature close to the setting temperature in cooling mode 4
- If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine 4
- In dry mode fan speed will be automatically varied 4
- In heating mode the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops 4
- Main points of operation 4
- Minute protection function 4
- Operation of air conditioner 4
- Please check the following things about your air conditioner before making a service call 4
- Remote control 4
- There is a telecommunication interface for remote control on the control panel of the indoor unit after the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector the air conditioner will be computerized and controlled from a far away place 4
- Trouble shooting 4
- Unit fails to start 4
- Variation of fan speed 4
- When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 4
- Defrosting function 5
- In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off 5
- In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes during defrosting both indoor and outdoor fan will stop running when defrosting finished air condi tioner will automatically back to running 5
- Main points of operation 5
- Power failure compensation to be applied for a necessary situation 5
- Prevent cool air blowing off 5
- Remote controller units please press the remote controller botton code to choose the program of code b 5
- The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects 5
- The followings are not malfuncition 5
- Trouble shooting 5
- Air filter inside of the inlet grille 6
- Air inlet grille 6
- Electrical box 6
- Indoor unit 6
- Installation procedures 6
- Name of each part 6
- Operating control panel 6
- Piping connection 6
- Swing louver air flow direction can be adjusted by using the swing button on the remote controller 6
- Below are listed four kinds of safety cautions and suggestions 7
- Carefully read the following information in order to operate the air conditioner correctly 7
- Caution 7
- Install ornament panel on indoor unit 7
- Installation of ornament panel 7
- Installation procedures 7
- Instruction 7
- Limits of panel board installation 7
- Safety cautions 7
- Warning 7
- Cautions for the water drainage lifting pipe 8
- Installation of water drainage pipe 8
- Installation procedures 8
- Safety cautions 8
- Warning 8
- After installation on the ceiling 9
- Caution 9
- Clean indoor unit 9
- Clean the air filter 9
- Clean the unit 9
- In the case of ceiling already exists 9
- Installation of indoor unit 9
- Installation procedures 9
- Lug two corners of the filter at the same time pull off the filter 9
- Maintenance 9
- Installation preparation 10
- Installation procedures 10
- Maintenance 10
- Post season care 10
- Pre season care 10
- Seasonal reserve 10
- Selection of installation place 10
Похожие устройства
- Haier AB182FCAIA Сервис мануал
- Haier AC182FCAHA Сервис мануал
- Haier AE072FLAIA Сервис мануал
- Haier AE092FLAIA Сервис мануал
- Haier AE122FLAIA Сервис мануал
- Haier AE142FLAIA Сервис мануал
- Haier AE182FLAIA Сервис мануал
- Haier AE242FLAIA Сервис мануал
- Haier AE072FCAMA Сервис мануал
- Haier AE092FCAMA Сервис мануал
- Haier AE122FCAMA Сервис мануал
- Haier AE142FCAMA Сервис мануал
- Haier AE182FCAMA Сервис мануал
- Haier AE212FCAMA Сервис мануал
- Haier AE242FCAMA Сервис мануал
- Haier AS072FCAIA Сервис мануал
- Haier AS092FCAIA Сервис мануал
- Haier AS122FCAIA Сервис мануал
- Haier AS142FCAIA Сервис мануал
- Haier AS182FTAHA Сервис мануал