Haier AB182FCBHA [15/21] Customers how to operate and maintain the unit
![Haier AB182FCAHA [15/21] Customers how to operate and maintain the unit](/views2/1821681/page15/bgf.png)
13
Unit shall be grounded. But grounding shall not be connected to gas pipe
water pipe, telephone line. Poor grounding will cause electric shock.
Be sure to install a leakage breaker to avoid electric shock.
Arrange water drainage according to this Manual. Cover pipe with insulation materials in case
dew may occur. Unproper installation of water drainage will cause water leakage and wer your furniture.
To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and ou
tdoor unit, connecting wire and power line. (If the radio wave is relatively strong, 1 m is not enough
to reduce noise).
Don't install unit in following places:
(a) Oil mist or oil gas exists, such as kitchen, or, plastic parts may got aged, or water leakage.
(b) Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion,
causing leakage.
(c) Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit
(d) Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter
might cause fire accident.
Meanings of Warning and Cautions:
Warning! Serious injury or even death might happen, if it is not observed.
Caution! Injury to people of damages to machine might happen, if it is not observed.
CAUTION!
CAUTIONS:
To ensure proper installation, read "Cautions" carefully before
working. After
installation, start the unit correctly and show
customers how to operate and
maintain the unit.
Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will
cause water leakage, electric shock or fire.
Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire
accident.
Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or
unit falling down may happen.
Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries.
When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may
cause unit to fall down.
All electric work shall be done by experienced people as per eocal code, regulations and this Manual.
Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric
shock or fire accident.
All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force
will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident.
Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to
avoid overheat, electric shock or even fire accident.
In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room.
Poisonous gas will occur when meet with fire.
Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas
when meet heat source as heater, oven, etc.
Cut power supply before touching terminal bolck.
WARNING!
Earthing
Don't fail to show customers how to operate unit.
Refer to paper pattern when installing unit.
Cautions for the installation personnel
Installation Procedure
Содержание
- Cassette type air conditioner 1
- No 010573643 b 1
- Operation installation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Carefully read the following information in order to operate the airconditioner correctly 5
- Cautions 5
- Safety cautions 5
- Warning 5
- Cautions 6
- Introduction to spare parts 7
- Caution 8
- Clean indoor outdoor unit 8
- Clean the air filter 8
- Clean the unit 8
- Maintenance 8
- Maintenance 9
- Post season care 9
- Pre season care 9
- Seasonal reserve 9
- The followings are not malfuncition 10
- Trouble shooting 10
- Please check the following things about your air conditioner before making a service call 11
- Trouble shooting 11
- Unit fails to start 11
- Cooled air blown out when heating 12
- Insufficient cooling 12
- Insufficient cooling or heating 12
- When trouble happens 12
- Attention after finishing installation confirm no refrigerant leakage 13
- Customer need to know 13
- Using directions 13
- Caution 14
- Installation 14
- Installation procedure 14
- Location 14
- Operating noise 14
- Warning 14
- Wiring 14
- Caution 15
- Cautions 15
- Customers how to operate and maintain the unit 15
- Don t fail to show customers how to operate unit 15
- Installation procedure 15
- Meanings of warning and cautions 15
- Warning 15
- Warning serious injury or even death might happen if it is not observed 15
- Installation procedure 16
- Installation tools 16
- Standard accessories 16
- Before installation 17
- Installation procedure 17
- Selection of installation place 17
- Installation procedure 18
- Preparation for the installation 18
- Installation of indoor unit 19
- Installation procedure 19
- Level polythene pipe 19
- Accessory 20
- Apple refrigerant oil 20
- Clamp 3 20
- Cover the piping joint with seal pad 20
- Flare nut 20
- For gas pipe 20
- For liquid pipe 20
- Gas pipe 20
- Installation of water drainage pipe 20
- Installation procedure 20
- Insulator accessory 20
- Large size seal pad 20
- Liquid pipe 20
- Medium size seal pad 11 accessory 20
- Mm below 20
- Over 100 20
- Pipe size 20
- Piping joing 20
- Refrigerant piping 20
- Self provided stiff pipe 20
- Spanner 20
- Table 1 20
- Tape white self provided stiff pipe 20
- Tighten torque a mm flare shape 20
- Torque spanner 20
- Installation procedure 21
Похожие устройства
- Haier AB182FCBHA Сервис мануал
- Haier AC142FCBHA Сервис мануал
- Haier AC182FCBHA Сервис мануал
- Haier AE072FCAKA Инструкция по эксплуатации
- Haier AE072FCAKA Сервис мануал
- Haier AE092FCAKA Инструкция по эксплуатации
- Haier AE092FCAKA Сервис мануал
- Haier AE122FCAKA Инструкция по эксплуатации
- Haier AE122FCAKA Сервис мануал
- Haier AE142FCAKA Инструкция по эксплуатации
- Haier AE142FCAKA Сервис мануал
- Haier AE182FCAKA Инструкция по эксплуатации
- Haier AE182FCAKA Сервис мануал
- Haier AE212FCAKA Инструкция по эксплуатации
- Haier AE212FCAKA Сервис мануал
- Haier AE242FCAKA Инструкция по эксплуатации
- Haier AE242FCAKA Сервис мануал
- Haier AE092FCAHA Инструкция по эксплуатации
- Haier AE092FCAHA Сервис мануал
- Haier AE182FCAHA Инструкция по эксплуатации