Safety Precautions
Read this ìsafety precautionsî carefully and thoroughly before implementation to ensure proper installation.
These precautions whose marks and contents as the following MUST be complied with for they include
important points concerning safety.
Contents marked with this sign concern personal safety of the user. Improper
operation can cause personal death or injury.
Warning!
Notice!
Contents marked with this sign concern safety of the product and user. Improper
operation can cause personal injury or damage of machine.
Trial run MUST be done after installation of the assembly to ensure no disorders occur. Meanwhile,
explain method of use and trouble-shooting to the user according to the operation manual.
In addition, this installation instruction and operation manuals should be kept by the user.
Warning!
Installation MUST be implemented by authorized organization and professional personnel.
Unauthorized installation may cause water leakage, electric shock and fire hazard etc.
Installation MUST be executed in accordance with this installation manual.
Improper installation may cause water leakage, electric shock and fire hazard etc.
Ask installation personnel to do preventions against leakage of refrigerant. While installing in
small room, proper preventions should be made to restrict leaking refrigerant within thickness
limit even leakage occurs. Contact authorized organizations and ask them to do such prevention.
Leakage of refrigerant exceeding thickness limit can easily cause hazard of oxygen shortage.
Location of installation should be strong enough to bear the weight of machine, which cannot be
installed on unspecified metal structures (e.g. burglarproof net)
Installation support of insufficient strength can cause falling of the machine and personal injuries.
Install as required to guard against typhoon, earthquake etc.
Installation not as required can cause overturn of the machine resulting accidents.
If thereís any leakage of refrigerant during installation, ventilation measures should be made
accordingly.
Contact between refrigerant vapor and fire can produce poisonous gas.
Ensure thereís no leakage of refrigerant after finishing installation.
If refrigerant vapor leaking indoors and contacts with fire sources such as blowing warmer and
stove etc., poisonous gas can be produced.
Use special circuit of power supply during installation and make fixed wiring layout according
to national wiring standard by certified electricians. Insufficient capacity of power supply circuit
or improper wiring layout can cause electric shock and fire hazards.
Wiring layout MUST apply specified power cables and be grounded reliably. Ensure reliability
of connections in parts of terminals for improper connection or fixing can cause fire hazard etc.
MUST be grounded.
Grounding line CANNOT be connected to gas pipe, tapping pipe, lighting rod or earth of telephone
etc.
Improper grounding can cause electric shock.
1
Содержание
- Safety precautions 2
- Notice 3
- Selection of installation place 3
- Installation in under ceiling 4
- Installation of air conditioner 4
- Installation of suspending bolts 4
- Prior to installation 4
- Directly use angle iron to set supporting angle iron use inlet hinge joint inlet plug or inlet bolt 5
- Fasten hexagon bolt and fix the air conditioner 5
- Insert hexagon bolt into carved fillet 5
- Install beam wood on the girder and set suspending bolts 5
- Installation of air conditioner 5
- Installation of air conditionert 5
- Installation of attached hexagon bolt 5
- Installation position of suspending bolts 5
- Installation status of supporting frame 5
- Internal suspension ac092 122 142 162feaha ac092 122 142 162febha 5
- Internal suspension ac182 242 282feaha ac182 242 282febha 5
- Please refer to positions of suspending bolts printed on installation paste board of ac092 122 142 162feaha ac092 122 142 162febha type 5
- Steel structure old concrete building 5
- Wood building new concrete building 5
- Installation of floor console 6
- Refrigerant distribution tube 7
- Requirentents 8
- Undulation 8
- Electric wiring 9
- Remote controller wire 9
- Code switch aw02 on base board of indoor unit has the function of setting centralized control address group number group number can be set by changing ì on offî status in ì 1 6î code positions code switch sw02 and its dialing codes are shown as following diagram 10
- One set of remote controller can control a group of 16 indoor unit at the most refer to electrical wiring layout items for wiring layout between indoor unit arrange wires between remote controller and indoor unit according to the following sequence 1 set number setting switch sw01 on pc board of each indoor unit with number 1 as ì 1î number 2 as ì 2î ö ö the machine directly connecting remote controller must be set as number 1î number 1 is the host while others are subsidiaries 2 connect terminals a b c of the remote controller with that of number 1 indoor unit respectively according to same numbers 3 connect terminals b c of number 1 indoor unit with that of number 2 respectively according to same numbers 4 connect terminals b c of number 2 indoor unit with that of number 3 respectively according to same numbers 5 by analogy of the above stop until connecting to terminals b c of number 16 at the maximum 6 disassemble short connection wire to cn12 terminal on control base board of numb 10
- Operation control 10
- Relation between combination of ì on offî status in ì 1 6î code positions and group number are shown as in right table when ì 7î position of sw02 is in ì offî status group number can be set either by dialing codes on sw02 or with circuit controller while ì 7î position of sw02 is in ì onî status group number can only be set either by dialing codes on sw02 10
- Requirement 10
- Setting of group number of indoor subassemblies 10
- Solution of group control 10
- Wires of remote controller between indoor unit should be power cord more than 1mm with length less than 500 m total length from remote controller to number 16 machine 10
- Settings of heating temperature compensation usage of switch sw03 11
- Usage of emergency switch usage of switch sw04 11
- Disorders in trial run 12
- Notice 12
- Requirement 12
- Trial run 12
Похожие устройства
- Haier AC092FEAHA Инструкция по эксплуатации
- Haier AC092FEBHA Инструкция по монтажу
- Haier AC092FEBHA Инструкция по эксплуатации
- Haier AC122FEAHA Инструкция по монтажу
- Haier AC122FEAHA Инструкция по эксплуатации
- Haier AC122FEBHA Инструкция по монтажу
- Haier AC122FEBHA Инструкция по эксплуатации
- Haier AC162FEAHA Инструкция по монтажу
- Haier AC162FEAHA Инструкция по эксплуатации
- Haier AC162FEBHA Инструкция по монтажу
- Haier AC162FEBHA Инструкция по эксплуатации
- Haier AC182FEAHA Инструкция по монтажу
- Haier AC182FEAHA Инструкция по эксплуатации
- Haier AC182FEBHA Инструкция по монтажу
- Haier AC182FEBHA Инструкция по эксплуатации
- Haier AC242FEAHA Инструкция по монтажу
- Haier AC242FEAHA Инструкция по эксплуатации
- Haier AC242FEBHA Инструкция по монтажу
- Haier AC242FEBHA Инструкция по эксплуатации
- Haier AC282FEAHA Инструкция по монтажу