Haier HC60C1VAR — инструкция по запуску и подключению системы охлаждения [12/17]
Превью страниц
Страница 12 /
17
![Haier HC42C1VAR [12/17] Electrical wiring](/views2/1820071/page12/bgc.png)
1.Fully open both shutoff valves.
2.Connect service gage manifold to the valve service
ports, being sure to evacuate lines.
3.Startup the system (Refer to the Section 7 - "System
Startup"). Run system at least 10 minutes to allo
pressure to stabilize.
4.Temporarily install thermometer on suction (large)
line near condensing unit. Be sure of good contact
between thermometer and line. Wrap thermometer
with insulating material to assure accurate reading.
5.Refer to Table 8 for proper system superheat. Add
charge to lower superheat. Remove charge to raise
superheat.
Carefully remove gage lines.
10
Table 8:System charging table by superheat
6.4.ELECTRICAL WIRING
! WARNING -
A means of strain relief must be installed to this appliance at the electrical service entrance.
Make sure that interconnecting wires between indoor and outdoor units meet the standards, codes
and regulations. Incomplete connection or fixing of the wire could result in a fire.
A means of strain relief must be installed to this appliance at the electrical service entrance.
Do not use intermediate connection of the power cord or the extension cord and do not connect
many devices to one AC outlet. It could cause a fire or an electric shock due to defective contact,
defective insulation, exceeding the permissible current, etc.
Perform electrical work according to the installation manual and be sure to use an exclusive
circuit. If the capacity of the power circuit is insufficient or there is incomplete electrical work, it
could result in a fire or an electric shock.
Ground the unit. Do not connect the ground to a gas pipe, water pipe, lighting rod or telephone
ground. Defective grounding could cause an electric shock.
Electrical installation will consists of power supply wiring to the condensing unit and control wiring
between thermostat, indoor unit and the condensing unit. All wiring must be in accordance with National
Electrical Code and/or local ordinances that may apply.
(See unit wiring diagram furnished with this instruction).
Note: Some states need the power supply wiring within special tybe be careful to use the waterproof
tube when installation the outdoor unit power supply wiring.(See the figure 4)
System Superheat
Ambient Return Air Temperature ( F)
Temperature At 65 70 75 80 85
Condenser Inlet ( F)
60 17 25 30 33 37
65 13 19 26 32 35
70 5 14 20 28 32
75 5 10 17 25 29
80 5 12 21 26
85 5 10 17 20
90 7 12 18
95 5 5 5
100 5 5
Figure 4-1 Figure 4-2
Содержание
44- Central air conditioner
- Installation operation manual
- Warning
- Table of content
- Nomenclature for model number
- Introduction
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 1 for 10 seer systems respectively
- Table 1
- Specification
- Model hc18 60a1var s
- Model hc18 60c1var table 3
- Figure 1
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 3 for 12 seer systems respectively
- Table 2 system cooling capacity
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 5 for 13 seer systems respectively
- Table 6 system cooling capacity
- Table 5
- Table 4 system cooling capacity
- Model hc18 60d1var
- Unit inspection
- Installation
- Equipment protection from environment
- Liquid line does not necessarily need insulation however if they are exposed to high ambient temperatures i e kitchen boiler rooms hot attics rooftop surface then they should be insulated make sure to use the proper size tubing for the liquid line to prevent liquid refrigerant flashing to a vapor within the liquid line
- Line insulation suction line requires insulation in order to prevent condensation from forming on the piping and to prevent heat gain caused by surrounding air generally 3 8 wall thickness of armflex or equivalent is satisfactory in severe application hot high humidity areas greater thickness may be required apply the line insulation by sliding it on the sealed tuing before cutting and making connections
- Figure 3
- Do not allow the vapor line and liquid line to touch together this would cause an undesirable heat transfer resulting in capacity loss and increased power consumption
- Electrical wiring
- System startup
- Operation
- Miscellaneous
- Wh white yl yellow
- Vac common
- Use copper conductors only warning cabinet must be permanently grounded and all wiring to conform to i e c n e c c e c c l c and local codes as applicable replacement wire must be the same gage and insulation type as original wire
- Pu purple rd red vi violet
- Optional low high pressur e switches
- Line volta ge factory standard field installed optional low voltage factory standard field installed optional
- Hc18 60a1var s hc18 60c1var hc18 60d1var
- Ha cool off heat
- Compressor
- Compress or protect 3 min time delay
- Component codes bcr blower control relay bcap run capacitor blower motor cc compressor contactor cch crankcase heater optional chs crankcase heater switch optional cmpr compressor hps high pressure switch lps low pressure switch ibm indoor blower motor ofm outdoor fan motor rcap run capacitor compressor rvs reversing valve solenoid stcap start capa citor optional strly start relay optional strth start thermistor optional tran transformer 230 208 selectable
- Color codes bk black bl blue gy gray
- Br brown gr green or orange
- Air conditioner wi ring diagram
Похожие устройства
-
Haier HC48C1VARРуководство по эксплуатации -
Haier HC42C1VARРуководство по эксплуатации -
Haier HC36C1VARРуководство по эксплуатации -
Haier HC30C1VARРуководство по эксплуатации -
Haier HC60A1VARСервис мануал -
Haier HC48A1VARСервис мануал -
Haier HC42A1VARСервис мануал -
Haier HC36A1VASСервис мануал -
Haier HC30A1VARСервис мануал -
Haier HC24A1VARСервис мануал -
Haier HC18A1VARСервис мануал -
Haier HC60A1VARРуководство по эксплуатации
Подробное руководство по запуску системы охлаждения, подключению манометра и электрической проводке. Узнайте, как правильно установить и настроить оборудование для безопасной работы.