ELECTRIC HEATER KIT
RD
BL
Air Conditioner Wi ring Diagram
1) Confi rm system selection. Opti onal com ponents m ay be field or factory installed.
2) If LPS and/or HPS not installed or removed, a ju mper wire must be present across circu it for syst em to operate.
3) For proper syste m operation, consul t indo or unit and outdoor unit installation inst ructi ons to confirm syst em match up and blower spe ed selection.
4) Alternat e double pole contac tor used on some syst ems.
5) Only one sta rt assist method to be used at a time, consul t outdoo r unit inst allation instr ucti ons for application information. Use only f actory approved accesso ries.
6) Optional OFM com ponents m ay connect capac itor common and motor com mon, for r ecipr ocati ng compres sor ther e may have cran kcase heat er co nsu lt outdoor unit inst allation
instruct ions for details.Select the run ning capacitor(one or dual)and connect.If IFM or OFM only have on e capacit or wire,co nnect Com wire t o cap acitor.
7) Indoor unit shipped w ithout optional electric heater kit. To inst all optional heater ki t,remove po wer pig tail up to 9 pin plug. Inst all heater kit and con nect with mating 9 pin plu g. Run
syst em power connect ions directly to electric heater kit power terminals. Consult heater kit inst allation instructions for complete details.
RD
24VAC COMMON
COMPRESSOR
BL
YL
208/230V
60Hz 1PH
C
BL
BL
YL
YL
Y
2
YL
P3
P2
P1
6
RD
R
L1
GND
L2
BK
BK
WH
C
S
CC
4
RD
YL
2
1
NC
Optional
Low & High
Pressur e
Switches
LPS
HPS
Compress or
Protect 3 Min.
Time Delay
BCAP
RD-LO
RD
L2
RD
OR
BK-HI
M
IBM
3
GR
PU
L1
BK
BK
R
S
BR
BR
208
COM
BL
R
TRAN
COM
230
7
BL
5
3
RD
NO
GR
8
6
4
OFM
M
BK
PU
PU
BR
6
S
R
BR
L1
L2
GND
60Hz 1PH
208/230V
WH
BK
BCR
1
BK
2
RD
BRK
BK
L2
RD
RD
FL
L1
BK
FL
USE COPPER CONDUCTORS ONLY
WARNING CABINET MUST BE PERMANENTLY GROUNDED
AND ALL WIRING TO CONFORM TO I.E.C.,N.E.C.,C.E.C.,
C.L.C. AND LOCAL CODES AS APPLICABLE.
REPLACEMENT WIRE MUST BE THE SAME GAGE AND
INSULATION TYPE AS ORIGINAL WIRE.
COMPONENT CODES
BCR - BLOWER CONTROL RELAY
BCAP - RUN CAPACITOR BLOWER MOTOR
CC - COMPRESSOR CONTACTOR
CCH - CRANKCASE HEATER (OPTIONAL)
CHS - CRANKCASE HEATER SWITCH (OPTIONAL)
CMPR - COMPRESSOR
HPS - HIGH PRESSURE SWITCH
LPS - LOW PRESSURE SWITCH
IBM - INDOOR BLOWER MOTOR
OFM - OUTDOOR FAN MOTOR
RCAP - RUN CAPACITOR COMPRESSOR
RVS - REVERSING VALVE SOLENOID
STCAP - START CAPA CITOR (OPTIONAL)
STRLY - START RELAY (OPTIONAL)
STRTH - START THERMISTOR (OPTIONAL)
TRAN - TRANSFORMER
230/208 SELECTABLE
R
H
S
-
1
COLOR CODES
BK - BLACK BL - BLUE GY - GRAY
BR - BROWN GR- GREEN OR - ORANGE
PU - PURPLE RD - RED VI - VIOLET
WH - WHITE YL - YELLOW
INDOOR FAN CONTROL
HEAT CONTROL
C
R
Y
W
G
WH
C
BL
G
W2
BL
BR
W
CA
RHS-2
TS
ON
AUTO
LED
F
A
N
COOL
OFF
HEAT
S
W
-
2
HA
COOL
OFF
HEAT
S
W
-
1
LINE VOLTA GE
FACTORY STANDARD
FIELD INSTALLED
OPTIONAL
LOW VOLTAGE
FACTORY STANDARD
FIELD INSTALLED
OPTIONAL
WH
PU
2
2
BK
1
1
RD
3
3
4
BL
3
5
BR
5
5
BL
4
4
7
BR
6
6
6
WH
BK
OPTIONAL
BK
RD
RD
RD
RD
TL
TL
RESISTANCE
14
HC18-60A1VAR/S
HC18-60C1VAR
HC18-60D1VAR
Содержание
44- Central air conditioner
- Installation operation manual
- Warning
- Table of content
- Nomenclature for model number
- Introduction
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 1 for 10 seer systems respectively
- Table 1
- Specification
- Model hc18 60a1var s
- Model hc18 60c1var table 3
- Figure 1
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 3 for 12 seer systems respectively
- Table 2 system cooling capacity
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 5 for 13 seer systems respectively
- Table 6 system cooling capacity
- Table 5
- Table 4 system cooling capacity
- Model hc18 60d1var
- Unit inspection
- Installation
- Equipment protection from environment
- Liquid line does not necessarily need insulation however if they are exposed to high ambient temperatures i e kitchen boiler rooms hot attics rooftop surface then they should be insulated make sure to use the proper size tubing for the liquid line to prevent liquid refrigerant flashing to a vapor within the liquid line
- Line insulation suction line requires insulation in order to prevent condensation from forming on the piping and to prevent heat gain caused by surrounding air generally 3 8 wall thickness of armflex or equivalent is satisfactory in severe application hot high humidity areas greater thickness may be required apply the line insulation by sliding it on the sealed tuing before cutting and making connections
- Figure 3
- Do not allow the vapor line and liquid line to touch together this would cause an undesirable heat transfer resulting in capacity loss and increased power consumption
- Electrical wiring
- System startup
- Operation
- Miscellaneous
- Wh white yl yellow
- Vac common
- Use copper conductors only warning cabinet must be permanently grounded and all wiring to conform to i e c n e c c e c c l c and local codes as applicable replacement wire must be the same gage and insulation type as original wire
- Pu purple rd red vi violet
- Optional low high pressur e switches
- Line volta ge factory standard field installed optional low voltage factory standard field installed optional
- Hc18 60a1var s hc18 60c1var hc18 60d1var
- Ha cool off heat
- Compressor
- Compress or protect 3 min time delay
- Component codes bcr blower control relay bcap run capacitor blower motor cc compressor contactor cch crankcase heater optional chs crankcase heater switch optional cmpr compressor hps high pressure switch lps low pressure switch ibm indoor blower motor ofm outdoor fan motor rcap run capacitor compressor rvs reversing valve solenoid stcap start capa citor optional strly start relay optional strth start thermistor optional tran transformer 230 208 selectable
- Color codes bk black bl blue gy gray
- Br brown gr green or orange
- Air conditioner wi ring diagram
Похожие устройства
-
Haier HC48C1VARРуководство по эксплуатации -
Haier HC42C1VARРуководство по эксплуатации -
Haier HC36C1VARРуководство по эксплуатации -
Haier HC30C1VARРуководство по эксплуатации -
Haier HC60A1VARСервис мануал -
Haier HC48A1VARСервис мануал -
Haier HC42A1VARСервис мануал -
Haier HC36A1VASСервис мануал -
Haier HC30A1VARСервис мануал -
Haier HC24A1VARСервис мануал -
Haier HC18A1VARСервис мануал -
Haier HC60A1VARРуководство по эксплуатации