Panasonic CS-ME12CB1P Сервис мануал онлайн

1 Features 3
2 About Lead Free Solder (PbF)
3
2.1. DISTINCTION OF PbF P.C. BOARD
3
2.2. CAUTION
3
3 Functions
4
3.1. REMOTE CONTROL
4
3.2. INDOOR UNIT
5
4 Product Specifications
7
5 Dimensions
8
© 2003 Matsushita Electric Industrial Co., Ltd. All
rights reserved. Unauthorized copying and
distribution is a violation of law.
CS-ME7CB1P
CS-ME10CB1P
CS-ME12CB1P
CS-ME14CB1P
CS-ME10CD3P
CS-ME14CD3P
5.1. Cassette Type 8
5.2. Grille
10
5.3. Duct Type
11
6 Refrigeration Cycle Diagram
12
7 Block Diagram
13
8 Wiring Diagram
14
8.1. Cassette Type (CS-
ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P)
14
8.2. Duct Type (CS-ME10CD3P/ME14CD3P)
15
Multi Air Conditioner
Please file and use this manual together with the service manual for Model No. CS-ME7CKPG, CS-
ME10CKPG, CS-ME12CKPG, CS-ME14CKPG, CS-ME18CKPG, CU-2E15CBPG, CU-2E18CBPG, CU-
3E23CBPG, CU-4E27CBPG, Order No. RAC0209005C2.
CONTENTS
Page Page
ORDER NO. RAC0312001A8
Содержание
- Contents 1
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p cs me10cd3p cs me14cd3p 1
- Multi air conditioner 1
- Page page 1
- Please file and use this manual together with the service manual for model no cs me7ckpg cs me10ckpg cs me12ckpg cs me14ckpg cs me18ckpg cu 2e15cbpg cu 2e18cbpg cu 3e23cbpg cu 4e27cbpg order no rac0209005c2 1
- About lead free solder pbf 3
- Caution 3
- Distinction of pbf p c board 3
- Features 3
- Functions 4
- Cooling 22 28 cu 2e15cbpg 1 9 0 5 1 3 6 0 7
- Cooling 22 28 cu 2e18cbpg 1 9 0 5 1 3 6 0 7
- Cooling 28 28 1 6 0 5 1 3 7 5 7
- Cooling 28 32 1 7 0 5 1 0 7 0 7
- Heating 1 6 0 1 1 7 6 5 7
- Heating 1 7 0 1 1 4 6 0 7
- Heating 1 9 0 1 1 2 6 5 7
- Indoor unit combination 7
- Min max 7
- Outdoor unit power input kw current a 7
- Product specifications 7
- Remarks 7
- Specifications are subject to change without notice for further improvement 7
- The combination 2 kw duct type x 2 and 2 kw duct type 2 kw wall type are same value 7
- The specifications are differ from wall type indoor units when 2 kw duct type is connected to cu 2e15cbpg and cu 2e18cbpg 7
- Dimensions 8
- Block diagram 13
- Wiring diagram 14
- Operation details functions protection 16
- Simultaneous operation control 16
- Airflow direction control cassette type only 17
- Indoor fan control 18
- Drain pump control 20
- Auto restart control 21
- Auto button 22
- Other indoor unit operation functions 22
- Self diagnosis display 25
- The diagnostic displays that appear when trouble has occurred can be checked using the remote control unit 25
- When trouble occurs operation is stopped automatically and the timer lamp blinks the diagnosis time has been reduced by warning the user by means of the blinking of the timer lamp 25
- Error cord 26
- Cassette type 30
- Installation instructions 30
- Required tools for installation works 30
- Install a sleeve of piping 31
- Selecting the installation location 31
- Selecting the piping 31
- To drill a hole in the wall and 31
- Connecting and insulating the refrigerant piping 32
- Connecting the drain piping 32
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p cs me10cd3p cs me14cd3p 32
- Installation dimensions 32
- Installing the indoor unit 32
- Attaching the decorative grille 33
- Connecting the indoor outdoor connecting cable 33
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p cs me10cd3p cs me14cd3p 33
- Using the pattern 8 33
- English 34
- F612424 34
- Matsushita electric industrial co ltd 34
- Duct type 35
- Installation instructions 35
- Required tools for installation works 35
- Attaching the remote control holder to the wall 36
- Caution 36
- Indoor unit accessory parts 36
- Indoor unit installation location remote control mounting location 36
- Other items to be prepared locally purchased 36
- Required materials 36
- Selecting the installation location 36
- Selecting the piping 36
- To drill a hole in the wall and install a sleeve of piping 36
- Caution 37
- Ceiling opening and hanging bolt locations 37
- Front view 37
- Installation diagram 37
- Installing the indoor unit installation embedded in the ceiling 37
- Preparing to install the indoor unit 37
- Right view 37
- Top view from above the ceiling 37
- View from below and behind the unit 37
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p cs me10cd3p cs me14cd3p 38
- Installation in the ceiling 38
- Mounting section view 38
- Mounting the receiver 38
- Securing the hanging bolts 38
- Switching the high state switch sw2 38
- Caution 39
- Check the drainage 39
- Connecting and insulating the refrigerant piping 39
- Connecting the drain piping 39
- Connecting the indoor outdoor connecting cable 39
- Female side male side 39
- English 40
- F612425 40
- Web site http www panasonic co jp global 40
- Before operation 41
- Contents 41
- Convenience operations 41
- For details about the following items carefully read the operating instructions attached at the outdoor unit for model cs me7ckpg 41
- Helpful information 41
- Operating instructions 41
- Points to note 41
- Safety precaution 41
- After connecting the power supply press button to select operating mode 42
- Convenience operation convenience operation convenience operation convenience operation 42
- Increase decrease 42
- Please also refer to fan speed air swing adjustment chapters 42
- Press one more time 42
- When heating cooling dry are not required 42
- When it is cold 42
- When it is hot 42
- When it is humid 42
- Auto restart control 43
- Indoor unit 43
- Model number 43
- Names of parts and preparations 43
- Odour wash indication lamp green 43
- Power indication lamp green 43
- Remote control signal receiver 43
- Timer indication lamp orange 43
- Cassette type 44
- I when the intake grille is open 44
- To close press in the 3 places shown 44
- To open press in the 3 places shown 44
- I receiver unit 45
- Indoor unit 45
- Names of parts and preparations 45
- Changing the fan speed 46
- Changing the vertical air flow directions 46
- Fan speed air swing adjustment 46
- I automatic fan speed 46
- Cooling dry air circulation 47
- Fan speed air swing adjustment 47
- Heating 47
- Horizontal air flow direction 47
- I setting automatic air flow directions 47
- Vertical air flow direction 47
- Care and maintenance 48
- Caution 48
- Cleaning the air filter 48
- Items sold separately 48
- Part name part number air filter cwd00228 48
- Care and maintenance 49
- Cassette type 49
- Cleaning the intake grille 49
- Must be removed from unit before washing 49
- Raise the intake grille keep hold of the intake grille when detaching it 49
- To fix the intake grille 49
- Wash and dry the intake grille 49
- Is it faulty no it is okay 50
- Is it okay consult your dealer 50
- Self diagnosis 50
- Troubleshooting 50
- Helpful information 51
- I after you have used wax 51
- I placing things around the indoor unit 51
- I when the remote control is not available and the batteries are out 51
- I when the unit is not operated for an extended period of time 51
- I when there is a power failure 51
- I when there is thunder in the vicinity 51
- Press the auto operation button 51
- Switch on the power supply 51
- Do not repair by yourself in case of malfunction of this appliance do not repair by yourself contact to the sales dealer or service dealer for a repair 52
- Do not use in an explosive atmosphere do not use this appliance in a potentially explosive atmosphere 52
- I notes if the unit is not going to be used for an extended period of time turn off the main power supply if it is left at the on position approximately 14 w of electricity will be used even if the indoor unit has been turned off with the remote control if operation is stopped then restart immediately the unit will resume operation only after 3 minutes 52
- If the supply cord is damaged or needed to be replaced it must be replaced by authorized service agent or a similarly qualified person in order to avoid a hazard 52
- Remove power plug or disconnect from the main power supply before servicing this appliance 52
- Safety precaution 52
- This appliance must be earthed 52
- Turn off the power isolation from main power supply pull off the power plug from the receptacle or switch off the breaker or switch off power disconnecting mean to isolate the equipment from the main power supply in case of an emergency 52
- Warning 52
- Cassette type indoor unit cs me7cb1p me10cb1p me12cb1p me14cb1p 53
- Detaching the fan motor and cross flow fan 53
- Disassembly of parts 53
- Detaching the drain pump 54
- Detaching the control board 55
- Detaching the louver motor 56
- Detaching the control board 57
- Detaching the upper and inner casing 57
- Duct type indoor unit cs me10cd3p me14cd3p 57
- Detaching the fan 58
- Detaching the fan motor and drain motor 58
- 10 11 12 63
- 14 15 16 63
- At product delivery 63
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p cs me10cd3p cs me14cd3p 63
- Electronic circuit diagram 63
- Remote control 63
- Remote control key 63
- Remote control transmission code change 63
- Air temp sensor 15k 3950 64
- Cassette type 64
- Cs me7cb1p cs me10cb1p cs me12cb1p cs me14cb1p 64
- Deice completion timer indication 5 min 0 64
- Drain motor 64
- Drain pump delayed off after operation off 64
- Drain pump forced on timer 0 5 min 64
- Electronic circuit diagram 64
- Fan motor 64
- Function 64
- Hot start forced completion hot start forced completion after deice auto mode judgment sampling time 64
- Hours off on timer cooling fc max 64
- Microprocessor a52d4956g123 64
- Min 18 sec 180 min 30 sec 60 min 120 min 180 min 300 min 420 min 64
- Min 20 min 6 min 64
- Pipe temp sensor 20k 3950 64
- Powerful mode operation time count anti dew formation control anti freezing control 64
- Receiver 64
- Sec 0 6 sec 64
- Sec 18 sec 64
- Sec 3 min 64
- Sec 3 sec 64
- Sensor characteristics 64
- Sleep mode timer shift 64
- Stepping motor 64
- Thermo off timer 64
- Time test mode 1 hour 1 min 30 min 3 sec 64
- Air temp sensor 15k 3950 65
- Cs me10cd3p cs me14cd3p 65
- Deice completion timer indication 5 min 0 65
- Display 65
- Drain motor 65
- Drain pump delayed off after operation off 65
- Drain pump forced on timer 0 5 min 65
- Duct type 65
- Electronic circuit diagram 65
- Fan motor 65
- Function 65
- Hot start forced completion hot start forced completion after deice auto mode judgment sampling time 65
- Hours off on timer cooling fc max 65
- Microprocessor a52d4956g123 65
- Min 18 sec 180 min 30 sec 60 min 120 min 180 min 300 min 420 min 65
- Min 20 min 6 min 65
- Pipe temp sensor 20k 3950 65
- Powerful mode operation time count anti dew formation control anti freezing control 65
- Sec 0 6 sec 65
- Sec 18 sec 65
- Sec 3 min 65
- Sec 3 sec 65
- Sensor characteristics 65
- Sleep mode timer shift 65
- Thermo off timer 65
- Time test mode 1 hour 1 min 30 min 3 sec 65
- Cs me7cb1p me10cb1p me12cb1p me14cb1p 66
- Exploded view 66
- Exploded view replacement parts list 66
- Cs me10cd3p me14cd3p 68
- Exploded view 68
Похожие устройства
- Panasonic CS-ME14CB1P Сервис мануал
- Panasonic CS-ME10CD3P Сервис мануал
- Panasonic CS-ME14CD3P Сервис мануал
- Panasonic WH-SDC09C3E8 Сервис мануал
- Panasonic WH-SDC12C9E8 Сервис мануал
- Panasonic WH-SDC14C9E8 Сервис мануал
- Panasonic WH-SDC16C9E8 Сервис мануал
- STARWIND SAF1252 Инструкция по эксплуатации
- STARWIND SAF1251 Инструкция по эксплуатации
- STARWIND SAF1232 Инструкция по эксплуатации
- STARWIND SAF1231 Инструкция по эксплуатации
- STARWIND TAC-07CHSA/XAA1 Инструкция по эксплуатации
- STARWIND TAC-09CHSA/XAA1 Инструкция по эксплуатации
- STARWIND TAC-12CHSA/XAA1 Инструкция по эксплуатации
- STARWIND TAC-18CHSA/XAA1 Инструкция по эксплуатации
- STARWIND TAC-24CHSA/XAA1 Инструкция по эксплуатации
- STARWIND SAW5522 Инструкция по эксплуатации
- STARWIND SAW5520 Инструкция по эксплуатации
- STARWIND SAW5521 Инструкция по эксплуатации
- STARWIND SHC1523 Инструкция по эксплуатации