Citizen CMP-30II — команды для выравнивания и установки табуляции в печати [25/71]

Citizen CMP-30II [25/71] In standard mode
- 25 -
ESC a
[Name]
Select justification
ASCII ESC a
n
Hex 1B 61
n
[Format]
Decimal 27 97
n
[Range]
0 n 2, 48 n 50
[Description]
Aligns all the data in one line to the specified position
n selects the justification as follows:
n
Justification
048 Left justification
149 Centering
250 Right justification
[Details]
x The command is enabled only when processed at the beginning of the line
in standard mode.
x If this command is input in page mode, the printer performs only internal flag
operation.
x This command has no effect in page mode.
x This command executes justification in the printing area.
x This command justifies the space area according to HT, ESC $ or ESC \
[Default]
n = 0
ESC D
[Name]
Set horizontal tab positions
ASCII ESC D
n1 nk NUL
Hex 1B 44
n1 nk 00
[Format]
Decimal 27 68
n1 nk 0
[Range]
1 n 255
0 k 32
[Description]
x Set is horizontal tab positions.
x n specifies the column number for setting a horizontal tab position from the
beginning of the line.
x k indicates the total number of horizontal tab positions to be set.
[Details]
x The horizontal tab position is stored as a value of [character width x n]
measured from the beginning of the line. The character width includes the
right-side character spacing, and double-width characters are set with twice
the width of normal characters.

Содержание

Узнайте, как использовать команды для выравнивания текста и установки горизонтальных табуляций. Подробности о форматах и диапазонах значений.