Citizen CMP-30II — переход от режимов печати: стандартный и страничный [31/71]

Citizen CMP-30II ESC Command Manual онлайн [31/71] 632088
- 31 -
[Default]
n = 0
ESC S
[Name]
Select standard mode
ASCII ESC S
Hex 1B 53
[Format]
Decimal 27 83
[Range]
[Description]
Switches from page mode to standard mode.
[Details]
x This command is effective only in page mode.
x Data buffered in page mode and the printable area developed in page mode
is cleared.
x This command is switches the setting for the following command (in which
the values can be set independently in standard mode and page mode) to
those for standard mode:
Set right-side character spacing: ESC SP, FS S
Select default line spacing : ESC 2, ESC 3
x The following commands are enabled only to set in standard mode.
Set printing area in page mode : ESC W
Set print direction in page mode : ESC T
x The following commands are ignored in standard mode.
Set absolute vertical print position in page mode : GS $
Set relative vertical print position in page mode : GS
x Standard mode is selected automatically when power is turned on, the
printer is reset, or command ESC @ is used.