Citizen CMP-30II — инструкция по настройке и калибровке сенсоров печати [34/41]

Citizen CMP-30II [34/41] Sensor calibration
34
NOTE
1. If the FEED button is pressed again within 3 seconds after printing ends,
the mode switches to the hexadecimal dump print mode. If the FEED
button is not pressed within 3 seconds, the self test ends automatically.
2. In the hexadecimal dump print mode, the received data is printed in
hexadecimal format. To end the hexadecimal dump print mode, turn off
the power.
3.10
Optimizing the Media Detection Level
(Sensor Calibration)
If media loading detection is unstable, try performing sensor calibration. The
procedure for sensor calibration is as follows.
(1) Check that the emulation and sensor settings are appropriate.
(2) Turn off the power.
In the case of label paper, peel off one label and make sure that
the peeled part comes to the reflection sensor position.
(3) Press the Power button while holding down the FEED button.
(4) Continue pressing both buttons and then release the Power
button when the Error LED goes out.
(5) Keep holding down the FEED button till sensor optimization
starts.