Citizen PHU-500 [166/186] Msw1 8 init signal

Citizen PHU-500 [166/186] Msw1 8 init signal
- 165 -
MSW1-5: CR code
[Outline] Select the printer when receiving CR(<0D>H) code.
OFF(0)
ON(1)
CR mode
Ignored
LF
ON (1) OPERATION:
Select the same operation with LF when receiving CR code.
Print data in print buffer and put linefeeds as specified.
OFF (0) OPERATION:
CR code may be ignored with no actions if receiving CR code.
MSW1-7: DSR signal
[Outline] Printer can be reset with DSR (serial I/F-6pin) signal. Select enable/disable of reset function with this signal.
OFF(0)
ON(1)
DSR Signal
Invalid
Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal
MSW1-8: INIT signal
[Outline] Printer can be reset with INIT (serial I/F-25Pin) signal. Select enable/disable of reset function with this signal.
OFF(0)
ON(1)
INIT Signal
Invalid
Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal