Starmix iPulse H 1235 Asbest Safe [27/324] Changing the folded filter cartridges

Starmix iPulse H 1235 Asbest Safe [27/324] Changing the folded filter cartridges
en- 27
* je nach Ausstattungsvariante
NOTE
Operating the rotary slide
Turn the red rotary slide inside to position CLOSE to the stop
on the marker ▲.
3
1
2
Place top section on the container and close the side latches.
7.4 Insert PE emptying and disposal bag*
NOTE
Only vacuum cleaners with dust class M and H with special
containers and rotary slide in the intake socket of types iPulse M,
iPulse H and iPulse tH-asbestos are suitable for the use of PE
emptying and disposal bags.
NOTE
Operating the rotary slide
Turn the red rotary slide inside to position OPEN to the stop
on the marker ▲.
Slide the ange completely over the intake socket.
Place the upper bag opening over the container rim.
1
2
3
Place top section on the container and close the side latches.
8 Changing the lter
8.1 Changing the folded lter cartridges
(see Quick Reference Guide ).
Clean the lter cartridges before changing them.
Turn the lock on the latch through 90° in a counter-clockwise
direction with a coin or similar object and push the latch to the
rear.
Fold up the cover.
Immediately isolate the folded lter cartridges that you have
removed in a dust-tight plastic bag and dispose of properly in
accordance with the requirements.
Insert new folded lter cartridges.
Lift the locking bracket up, fold down the cover and click in place
with light pressure.
9 Changing the motor protection lter
(see Quick Reference Guide ).
NOTE
If motor protection lter is contaminated, this indicates defective
lter cartridges.
Replace folded lter cartridges.
Replace motor protection lter or wash the motor protection
lter under owing water, dry and re-insert.
10 Transport
Remove suction hose.
Close off intake socket with cap.
Securely x the motor head to the container (close the side
latches).
Place the accessories in a suitable plastic bag and seal the plas-
tic bag or place it in the tool storage compartment.
Put the suction hose ends together so that no dirt particles leak
out.
Place the hose around the vacuum cleaner and clamp onto the
handle (see Quick Reference Guide).
11 Maintenance
NOTE
Switch off the vacuum cleaner and pull out the mains plug before
carrying out any maintenance work.
For maintenance by the user, the vacuum cleaner must be
- dismantled,
- cleanded and
- maintained,
as far as possible without creating any danger to the maintenance
personnel or other.

Содержание