Grundig GEBD19401BHI [6/76] If the product is produced with cable and plug

Содержание

The connection cable must not be clamped bent or trapped or come into contact with hot parts of the oven You may cause the oven to short circuit and catch fire as a result of the cable melting If the power cord is damaged it must be replaced by a qualified electrician Otherwise there is a risk of electric shock short circuit or fire The plug of the power cord should be easily accessible after installation but not over the hobs When wiring you must comply with national I local electrical regulations and use socket outlet I line and plug suitable for the Oven If the power limits of the product exceed the current carrying capacity of the plug and socket outlet I line you must connect the product directly to the fixed electrical installation without using the plug and socket outlet I line Make sure that fuse rating is compatible with the product Connection must comply with national regulations The mains supply data must correspond to the data specified on the type label of the product Open the front door to see the type label Power cable of your product must comply with the values in Technical specifications table If the product will be connected directly to the supply power If it is not possible to disconnect all poles in the supply power a disconnection unit with at least 3 mm contact clearance fuses line safety switches contactors must be connected and all the poles of this disconnection unit must be adjacent to not above the product in accordance with I EE directives Failure to obey this instruction may cause operational problems and invalidate the product warranty Additional protection by a residual current circuit breaker is recommended If the product is produced with cable and plug Your product is produced with mains cable and plug Connect the plug of your product to a grounded outlet and make the electrical connection If the product is produced with cable and without plug Connect the cord of product to supply power as identified below Brown black cable L Phase Blue cable N Neutral Green yellow cable E Ground If the product is produced without cable and plug A power cable that it is defined in the technical table home must be connected to product by following the instructions Power cable must not be longer than 2 m because of safety reasons Open the terminal block cover with a screwdriver Insert the power cable through the cable clamp below the terminal and secure it to the main body with the integrated screw on cable clamping component Connect the cables according to the N Neutral Blue L Live Phase Brown black E Ground Green yellow C Cable clamp After completing the wire connections close the terminal block cover Connect the power cable to supply power by routing it so that it will not contact the product and get squeezed between the product and the wall Prevention against possible fire risk Ensure all electrical connections are secure and tight to prevent risk of arcing Do not use damaged cables or extension cables

Скачать