ELECTRIC PLANER
EN
After replacing or rearranging the blades, perform a test turning on of the planer, taking precautions. If there is
more tool vibration, check that the blades are installed correctly.
ATTENTION!
When using standard replaceable blades there is no need to regulate the screws to adjust the
position of the blade 16 (pic. 1). If the cutting edge of the mounted blade does not lie in the
planer of the back base plate, use screws
16 to adjust the position of the blade, pre-loosening
the screws 15.
Electric motor care
You must be especially careful with the electric motor, avoid getting liquids and foreign objects inside the case.
Keep your ventilation holes clean, blow them regularly with compressed air or clean them with a brush. When
noticeable sparks appear, contact an authorized service center for diagnostics and possibly for the replacement
of carbon brushes.
ATTENTION!
Electric planers do not need additional lubrication. The construction uses sealed bearings
with grease lling, designed for the entire lifetime. Attempt of additional lubrication from
the user leads to the accumulation of dust and chips on moving parts, which leads to negative
consequences.
In case of any damage to the power cord turn the planer o immediately, carefully, without touching the places
of damage, disconnect it from the power supply.
ATTENTION!
Electrical planers use power cord with mounting type Y: for security it must be replaced by
authorized repair shop personnel.
Possible faults
Fault Probable cause Problem solution
The tool does not turn on.
Broken power cord or mounting
wire, power cord malfunction.
Call the service center.
Faulty switch. Call the service center.
Brush wear. Call the service center.
Circular  re on the collector.
Fault in the armature winding. Call the service center.
Wearout /”hang ” of brushes. Call the service center.
The engine of the planer works,
but the roll does not rotate.
Worn / broken drive belt. Call the service center.
When working smoke or smell
of burning insulation is generated
from the vent.
Interturn closure of armature
or stator windings.
Call the service center.
Malfunction of the electrical part
of the instrument.
Call the service center.
Increased machine vibration.
Damage or deformation
of the base plate.
Call the service center to replace
the base plate.
Faulty or improperly installed
tooling.
Replace or reinstall a tooling.