Bosch GIS 1000C (0601083300) [21/409] Technical data

Bosch GIS 1000C (0601083300) [21/409] Technical data
English | 21
Bosch Power Tools 1 609 92A 211 | (21.9.16)
Technical Data
Thermo detector GIS 1000 C GIS 1000 C
Article number
3 601 K83 3.. 3 601 K83 370
Working range
0.1–5m 0.1–5m
Measuring range
–Surface temperature
Contact temperature
–Ambient temperature
–Relative humidity
–40...+1000 °C
–40...+1000 °C
–10...+50 °C
0...100 %
–40...+1000 °C
–40...+1000 °C
–10...+50 °C
0...100 %
Measuring accuracy (typical)
Surface temperature
1)
–40...–20.1 °C
–20...–0.1 °C
0...+100 °C
>+100 °C
Ambient temperature
typical
Relative humidity
1)
<20%
20...60 %
60...90 %
±2.5 °C
±1.5 °C
±1 °C
±1 % (>400 °C2 %)
±1 °C
±3 %
±2 %
±3 %
±2.5 °C
±1.5 °C
±1 °C
±1 % (>400 °C2 %)
±1 °C
±3 %
±2 %
±3 %
Optic (relation of measuring distance :
measuring spot)
2) 3)
50 : 1 50 : 1
Laser class
22
Laser type (typically)
635 nm, <1 mW 635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
–at 1m distance
–at 5m distance
6mm
10 mm
6mm
10 mm
Batteries (alkali-manganese)
Battery pack (lithium-ion)
4 x 1.5 V LR6 (AA) (with battery adapter)
10.8 V/12 V
4x1.5VLR6 (AA)
Battery life
Batteries (alkali-manganese)
–Battery pack (lithium-ion)
3h
5h
3h
Number of images in internal image memory (typical)
>200 >200
Bluetooth®
Bluetooth® 4.0
(Classic and Low Energy)
4)
Bluetooth® 4.0
(Classic and Low Energy)
4)
USB port 2.0 2.0
Weight according to EPTA-Procedure 01:2014
0.55 kg 0.55 kg
Dimensions (length x width x height)
136 x 89 x 214 mm 136 x 89 x 214 mm
Permitted ambient temperature
–during charging
during operation
5)
–during storage
0...+45 °C
–10...+50 °C
–20...+70 °C
–10...+50 °C
–20...+70 °C
Recommended batteries
GBA 10,8V ...
GBA 12V ...
Recommended chargers
AL 11.. CV
GAL 12.. CV
OBJ_BUCH-2270-005.book Page 21 Wednesday, September 21, 2016 5:29 PM

Содержание