Troubleshooting – Causes and Corrective Measures
Rainwater Pump
Problem Possible Cause Corrective Measure
Warning triangle flash-
ing Red
Battery too hot/cold Allow to cool/warm
Warning triangle flash-
ing yellow
Dry-running protection has been activated Switch machine off and reposition pump so that
is fully submerged
Pump does not start Battery control box not fully closed Ensure that the battery control box cover is
closed and the locking handle is in the fully down
position
Battery not (properly) inserted Properly insert battery
Cable not (properly) connected Ensure that the plug is fully inserted into the con-
nection on the control box and the protective col-
lar is in place
Battery discharged Recharge battery
Pump/water frozen Remove pump and wait until ice has completely
melted
Pump running but no
or limited working
pressure/pulsating
pressure
Water filter clogged up Remove filter and clean
Insufficient water Check the water level and ensure that the pump is
fully submerged
Air in the pump/hose Remove any spray attachment and run the pump
with only hose attached until water flows
smoothly
Auto stop connections fitted Exchange connectors for non autostop type
Hose Blockage Check hose for kinks and blockages
Water leaking from
hose after pump use
Anti-siphon connector not fitted Fit the anti-siphoning connector provided
Anti-siphon connector not properly positioned Reposition the anti-siphon connector so that it is
positioned above the water level within the tank
Anti-siphon connector blocked Clean anti-siphon connector
Flashing red battery
charge indicator.
No charging procedure
possible
Battery contacts contaminated Clean the battery contacts(e.g. by inserting and
removing the battery several times) or replace
the battery
Battery defective Replace battery
Battery charge indic-
ator does not light up
on charge
Mains plug of battery charger not plugged in
(properly)
Insert mains plug (fully) into the socket outlet
Socket outlet, mains cable or battery charger de-
fective
Check the mains voltage; have the battery char-
ger checked by an authorised after-sales service
agent for Bosch power tools
Maintenance, Cleaning and Storage
Maintenance
Note: To ensure long and reliable service, carry out the fol-
lowing maintenance regularly.
u Repairs may only be carried out by authorised Bosch Ser-
vice Centres.
Check that covers and guards are undamaged and correctly
fitted. Carry out necessary maintenance or repairs before
using.
Regularly check for obvious defects such as loose fixings,
and worn or damaged components.
Storage in Winter (see figureN)
Switch off the pump and remove the battery from the bat-
tery control unit. Pull the pump with the connecting hose out
F 016 L81 984 | (27.02.2020) Bosch Power Tools