Orient ОС-103 [221/244] Message id

Orient ОС-201 [221/244] Message id
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 4. Logs Messages
ComNav Technology Ltd.
202
CNT-OEM-RM001, Rev 1.8
Reply (BINEX)
For more information on BINEX records, please refer to the website binex.unavco.org.
4.3.4.3 Record 0x7d Receiver Internal State
Description
BINEX Record 0x7d serves as a test bed for working out the details of ways of storing receiver
internal state variables, including, for example, internal temperature.
Subrecord 0x00: 0x7d-00
This subrecord is being developed for receiver internal state variables, e.g. internal
temperature, power, and so on.
Message ID
112
Recommended Input
log binex7d00b ontime 1
Supported Format
Binary
Reply (BINEX)
For more information on BINEX records, please refer to the website binex.unavco.org.
4.3.4.4 Record 0x7e Ancillary Site Data Prototyping
Description
BINEX Record 0x7e serves as a test bed for working out the details of new ways of storing
ancillary site data, including, for example, site meteorological (MET) data.
Subrecord 0x00: 0x7e-00
This subrecord is being developed for hold ancillary site data, e.g. site meteorological data
(pressure, temperature, humidity, etc.), local geophysical data (tilt, strain, etc.), and so on.
Message ID
113
Recommended Input
log binex7e00b ontime 5
Supported Format
binary
Reply (BINEX)
For more information on BINEX records, please refer to the website binex.unavco.org.