Orient ОС-103 [75/244] Undulationchoose undulation

Orient ОС-201 [75/244] Undulationchoose undulation
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 3. Compatible Commands
ComNav Technology Ltd.
56
CNT-OEM-RM001, Rev 1.8
3.2.40 UNDULATION Choose undulation
Format
UNDULATION <opt> [sep]
Description
This command permits user to either enter a specific geoidal undulation value. The undulation
values reported in the position logs are in reference to the ellipsoid of the chosen datum.
Parameters
opt Geoidal height model option, refer to Table 18l. Default value is EGM96’.
sep Undulation value required for the USER option, default value = 0.000.
Table 18.Geoidal Height (Undulation) Model
OPTION
ID
DESCRIPTION
table
0
Use the internal undulation table (same as EGM96)
USER
1
Use the user specified undulation value
OSU89B
2
Use the OSU89B undulation table
EGM96
3
Use global geoidal height model EGM96 table
Example
UNDULATION EGM96
UNDULATION OSU89B
UNDULATION USER 10.000000000
UNDULATION table
3.2.41 UNLOCKOUT Reinstate a satellite in the solution
Format
UNLOCKOUT <prn>
Description
This command allows a satellite which has been previously locked out (LOCKOUT command) to
be reinstated in the solution computation. If more than one satellite is to be reinstated, this
command must be reissued for each satellite reinstatement.