A. Introduction
This product is a battery-powered, true-rms, auto-ranging digital multimeter with
a 8000 counts, LCD display and backlight.
B. Safety Information
To avoid possible electrical shock, fire, or personal injury, please read all safety
information before you use the product.
(1) Do NOT exceed the “maximum value” indicated in the Specification.
(2) Examine the connection of the test leads and the insulation of the product
before measuring voltage higher than 36V DC or 25V AC.
(3) Disconnect the test leads from the circuit before changing the mode。
(4) Misuse of mode or range can lead to hazards, be cautious. “OL” will be shown
on the display when the input is out of range.
(5) Safety symbols:
C. Specifications
- 1 - - 3 -
- 4 -
- 2 -
General Specifications
Display
(LCD)
8000 counts
Ranging
Auto/Manual
Material
ABS
Update Rate
3 times/second
Ture RMS
√
Data Hold
√
Backlight
√
Low Battery Indication
√
Auto Power Off
√
Mechanical Specifications
Dimension
161*81*39mm
Weight
198g/227g(w/ batteries)
Battery Type
1.5V AA Battery * 2
Warranty
One year
Environmental Specifications
Operating
Temperature 0~40℃
Humidity
<75%
Storage
Temperature
-
20~60
℃
Humidity
<80%
Standard Accessories
Battery * 2pcs
Test Lead * 1 pair
Thermocouple probe * 1pc
English User Manual
Gift Box
D. Instruction
(1) Front Panel(see the picture on the right)
1. LCD display
2. Bottons
2a. HOLD & Backlight
To hold the current reading, push this button
and you will see “HOLD” on the display; push
again to cancel.
To turn on the backlight, push this botton for
more than 2 seconds; long-push again to turn
off.
2b. SELECT
To toggle between DCV/ACV, DCmV/ACmV/,
Resistance/Continuity/Diode/Capacitance,
Frequency(with low voltage)/Duty Cycle,
DCA/ACA, DCmA/ACmA, DCμA/ACμA, or
℃/℉, press this botton.
3. Rotary Switch: To change mode or range。
(from OFF, clockwise)
3a. OFF
3b. DC Voltage (V) /AC Voltage (V)
3c. DC Voltage (mV) /AC Voltage (mV)
3d. Resistance/Continuity/Diode/Capacitance
3e. Frequency (with low voltage)/DutyCycle
3f. DC Current (A) /AC Current (A)
3g. DC Current (mA) /AC Current (mA)
3h. DC Current (μA) /AC Current (μA)
3j. Temperature
4. 10A: Input terminal for current (A) measurements.
5. mA/μA: Input terminal for current (mA and μA) measurements.
6. COM: Common terminal for all measurements.
7. VΩHz: Input terminal for voltage, frequency, duty cycle, resistance, continuity,
diode, capacitance,and temperature measurements.
8. RANGE: push this botton to enter the manual range; each push increases the
range; when the highest range is reached, next push will go back to the lowest
range; to exit the manual range mode, press the button for 2 seconds.
9. REL: the product allows relative measurements for the Modes of Voltage, Current,
and Capacitance; push this button to enter the relative measurements mode;
push again to exit.
10. MAX/MIN: push the botton once to measure the MAX Value; push twice to
measure the MIN Value; push three times to measure the difference between
the two values; to exit the mode, push the botton for 2 seconds.
11. Hz%: push this button when the product is at the AC Voltage (V) Mode to enter
the Frequency (with high voltage) /Duty cycle Mode.
Electrical Specifications
Function Range
Resolution
Accuracy
MAX.Value
Other
DC Voltage
(V)
8.000V
0.001V
±(0.5%+3)
1000V
80.00V
0.01V
1000V
1V
DC Voltage
(mV)
80.00mV
0.01mV
800mV
800.0mV
0.1mV
AC VoltAge
(V)
8.000V
0.001V
±(1.0%+3)
750V
40Hz-1kHz
80.00V
0.01V
750V
1V
AC VoltAge
(mV)
80.00mV
0.01mV
800mV
800.0mV
0.1mV
DC Current
(A)
8.000A
0.001A
±(1.2%+3)
10A
10.00A
0.01A
DC Current
(mA)
80.00mA
0.01mA
800mA
800.0mA
0.1mA
DC Current
(μA)
800.0
μA
0.1
μA
8000μA
8000
μA
1
μA
AC Current
(A)
8.000A
0.001A
±(1.5%+3)
10A
40Hz-1kHz
10.00A
0.01A
AC Current
(mA)
80.00mA
0.01mA
800mA
800.0mA
0.1mA
AC Current
(μA)
800.0
μA
0.1
μA
8000μA
8000
μA
1
μA
Function Range Resolution Accuracy MAX.Value Other
Resistance
800.0
Ω
0.1
Ω
±(0.5%+3)
80MΩ
8.000k
Ω
0.001k
Ω
80.00k
Ω
0.01k
Ω
800.0k
Ω
0.1k
Ω
8.000M
Ω
0.001M
Ω
80.00M
Ω
0.01M
Ω
±(1.5%+3)
Capacitance
9.999nF
0.001nF
±(5.0%+20)
9.999mF
99.99nF
0.01nF
±(2.0%+5)
999.9nF
0.1nF
9.999
μF
0.001
μF
99.99
μF
0.01
μF
999.9
μF
0.1
μF
9.999mF
0.001mF
±(5.0%+5)
Frequency
99.99Hz
0.01Hz
±(0.1%+2)
9.999MHz
999.9Hz
0.1Hz
9.999kHz
0.001kHz
99.99kHz
0.01kHz
999.9kHz
0.1kHz
9.999MHz
0.001MHz
Duty Cycle
1%~99%
0.1%
±(0.1%+2)
Diode √
Continuity √
Temperature
(
-20~1000)℃
1
℃
±
(2.5%+5
)
1000℃
(
-4~1832)℉
1
℉ 1832℉
1
2a
2b
3
4
5
6
7
8
9
10
11
Содержание
- 1 3 4 2 1
- C specifications 1
- D instruction 1
- Khz 0 01khz 1
- Ma 0 1ma 1
- More than 2 seconds long push again to turn 1
- Nf 0 01nf 1
- User manual 1
- 1 do not operate the product around hot wet flammable explosive or magnetic 2
- 5 7 8 6 2
- A do not input voltage at the diode mode 2
- And limitation of liability 2
- B do not touch high voltage circuit during measurements 2
- Caution 2
- Connect the black test lead to the com terminal and connect the red test lead to 2
- Do not use the product when the batteries or the battery cover is not placed 2
- Limited warranty 2
- The rotary switch to the frequency mode or push select once to toggle to the 2
- Touch the probes to the desired test points of the circuit to measure the resistance 2
Похожие устройства
- Yli Electronic YM-280NT(LED) Спецификация
- Zotek VC15B+ Инструкция по эксплуатации
- Zotek VC17B+ Инструкция по эксплуатации
- Zotek ZT-KP2 Инструкция по эксплуатации
- Zotek ZT-5566 Инструкция по эксплуатации
- Zotek ZT-81 Инструкция по эксплуатации
- Zotek ZT-82 Инструкция по эксплуатации
- Zotek ZT-A2 Инструкция по эксплуатации
- Zotek ZT-5B Инструкция по эксплуатации
- Zotek ZT-M0 Инструкция по эксплуатации
- Zotek ZT922 Инструкция по эксплуатации
- Zotek ZT922SE Инструкция по эксплуатации
- Zotek VC921 Инструкция по эксплуатации
- Zotek ZT-203 Инструкция по эксплуатации
- Yli Electronic ISK-840B Спецификация
- Yli Electronic YM-500W Спецификация
- Yli Electronic YM-180N(LED) Спецификация
- Yli Electronic YM-180 Спецификация
- Yli Electronic YK-568L Инструкция по эксплуатации
- Utepo SF10P-FHM Инструкция по эксплуатации