NOTICE
NOTICE
Locate Reactor
1. Locate Reactor on a level surface. See
Dimensions, page 38, for clearance and mounting
hole dimensions.
2. Do not expose Reactor to rain.
3. Use the casters to move Reactor to a fixed location,
or bolt to shipping pallet and move with forklift.
4. To mount on a truck bed or trailer, remove casters
and secure rear axle with 15B805 mobile mounting
bracket (MB), available separately. Bolt bracket and
mounting feet (MF) directly to truck or trailer bed.
See Dimensions, page 38.
General equipment guidelines
Determine the correct size generator. Using the
correct size generator and proper air compressor
will enable the proportioner to run at a nearly
constant RPM. Failure to do so will cause voltage
fluctuations that can damage electrical equipment.
Ensure the generator matches the voltage and
phase of the proportioner.
Use the following procedure to determine the
correct size generator.
a. List system components that use peak load
requirements in watts.
b. Add the wattage required by the system
components.
c. Perform the following equation:
Total watts x 1.25 = kVA (kilovolt-amperes)
d. Select a generator size that is equal to or
greater than the determined kVA.
Size the power cord using the full load peak amps
listed in TABLE 1, page 20. Failure to do so will
cause voltage fluctuations that can damage
electrical equipment.
Use an air compressor with constant speed head
unloading devices. Direct online air compressors
that start and stop during a job will cause voltage
fluctuations that can damage electrical equipment.
Maintain and inspect the generator, air compressor,
and other equipment per the manufacturer
recommendations to avoid an unexpected
shutdown. Unexpected equipment shutdown will
cause voltage fluctuations that can damage
electrical equipment.
Use a wall power supply with enough current to
meet system requirements. Failure to do so will
cause voltage fluctuations that can damage
electrical equipment
Proper system setup, start up, and shutdown
procedures are critical to electrical equipment
reliability. The following procedures ensure steady
voltage. Failure to follow these procedures will cause
voltage fluctuations that can damage electrical
equipment and void the warranty.
To prevent damage from tipping over and falling,
proper care needs to be taken when lifting the Reactor.
Bolt Reactor to original shipping pallet, to keep stable,
before lifting.