Graco Reactor E-20 P29025 [37/42] Data reporting kit
![Graco Reactor E-20 P29025 [37/42] Data reporting kit](/views2/1900104/page37/bg25.png)
Accessories
312065V 37
Accessories
Feed Pump Kits
Pumps, hoses, and mounting hardware to supply fluids
to Reactor. Includes 246483 Air Supply Kit. See
309815.
246483 Air Supply Kit
Hoses and fittings to supply air to feed pumps, agitator,
and gun air hose. Included in feed pump kits. See
309827.
246978 Circulation Kit
Return hoses and fittings to make circulation system.
Includes two 246477 Return Tube Kits. See 309852.
246477 Return Tube Kit
Desiccant dryer, return tube, and fittings for one drum.
Two included in 246978 Circulation Kit. See 309852.
248669 Conversion Kit
Convert any E-XP2 to a E-30 with 15.3kW of heat.
Include new pumps, bearing, and fitting to accomplish
conversion. See manual 309574.
Heated Hoses
50 ft (15.2 m) and 25 ft (7.6 m) lengths, 1/4 in. (6 mm),
3/8 in. (10 mm), or 1/2 in. (13 mm) diameter, 2000 psi
(14 MPa, 140 bar) or 3500 psi (24 MPa, 241 bar). See
309572.
Heated Whip Hoses
10 ft (3 m) whip hose, 1/4 in. (6 mm) or 3/8 in. (10 mm)
diameter, 2000 psi (14 MPa, 140 bar) or 3500 psi (24
MPa, 241 bar). See 309572.
Fusion Spray Gun
Air purge gun, available in round or flat pattern. See
309550.
246085 Data Reporting Kit
Records actual temperature, temperature setpoint,
actual pressure, cycles, and diagnostic code data from
Reactor. Downloads data to PC with Microsoft
®
Windows 98 or later. See 309867.
248848 Data Reporting Kit
Records actual temperature, temperature setpoint,
actual pressure, cycles, and diagnostic code data from
Reactor. Downloads data to PC with Microsoft
®
Windows 98 or later. Does not include interface module.
See 309867.
Содержание
- Electric heated plural component proportioner 1
- For spraying polyurethane foam and polyurea coatings for professional use only 1
- Important safety instructions 1
- Not approved for use in explosive atmospheres or hazardous classified locations 1
- Operation 1
- Contents 2
- Systems 3
- Approvals 4
- E 20 and e xp1 series 210 ft 64 m maximum heated hose length including whip hose e 30 and e xp2 series 310 ft 94 m maximum heated hose length including whip hose 4
- E 20 series 4
- E 30 series 4
- E xp1 series 4
- E xp2 series 4
- Full load amps with all devices operating at maximum capabilities fuse requirements at various flow rates and mix chamber sizes may be less 4
- Maximum flow rate given for 60 hz operation for 50 hz operation maximum flow rate is 5 6 of 60 hz maximum flow 4
- Models 4
- Total system watts based on maximum hose length for each unit 4
- Related manuals 5
- Supplied manuals 5
- Danger 6
- Warning 6
- Warnings 6
- Warning 7
- Warning 8
- Warning 9
- Important isocyanate iso information 10
- Isocyanate conditions 10
- Changing materials 11
- Foam resins with 245 fa blowing agents 11
- Keep components a and b separate 11
- Material self ignition 11
- Moisture sensitivity of isocyanates 11
- Shown exposed for clarity wrap with tape during operation 12
- Typical installation with circulation 12
- Shown exposed for clarity wrap with tape during operation 13
- Typical installation without circulation 13
- Component identification 14
- Main power switch 15
- Red stop button 15
- Temperature controls and indicators 15
- Actual temperature key led 16
- Circuit breakers 16
- Heater zone on off keys leds 16
- Target temperature key led 16
- Temperature arrow keys 16
- Temperature displays 16
- Temperature scale keys leds 16
- Cycle count key led 17
- Motor controls and indicators 17
- Motor on off key led 17
- Park key led 17
- Pressure key led 17
- Psi bar keys leds 17
- Pressure arrow keys 18
- Pressure cycle display 18
- Spray adjustments 18
- General equipment guidelines 19
- Locate reactor 19
- Electrical requirements 20
- Grounding 20
- Table 1 electrical requirements kw full load amps 20
- Connect electrical cord 21
- Connect feed pumps 21
- Connect pressure relief lines 21
- Connect heated hose 22
- Install fluid temperature sensor fts 22
- Supply wet cups with throat seal liquid tsl 24
- Flush the equipment 25
- Operation 25
- Pressure relief procedure 25
- Load fluid with feed pumps 26
- Startup 26
- Set temperatures 27
- Set pressure 28
- Change pressure imbalance setting optional 29
- Spraying 29
- Table 2available pressure imbalance settings 29
- Shutdown 30
- Circulation through reactor 31
- Fluid circulation 31
- Circulation through gun manifold 32
- Jog mode 33
- Alarms 34
- Alarms turn off motor and heat zones turn main power 34
- By pressing 34
- Diagnostic codes 34
- E06 can be cleared by pressing for other codes 34
- Errors 34
- Motor control diagnostic codes 34
- Motor control diagnostic codes e21 through e29 appear on pressure display 34
- Note alarms can also be cleared except for code 23 34
- Note for hose zone only if fts is disconnected at startup display will show hose current 0a 34
- Reactor will continue to run press to clear an error will not recur for a predetermined amount of time varies for different warnings or until main power is 34
- See repair manual for corrective action 34
- Temperature control diagnostic codes 34
- Temperature control diagnostic codes appear on temperature display 34
- Then on 34
- There are two types of motor control codes alarms and warnings alarms take priority over warnings 34
- These alarms turn off heat e99 clears automatically when communication is regained codes e03 through 34
- To clear 34
- Turn main power off 34
- Turned off 34
- Fluid inlet strainer screen 35
- Maintenance 35
- Pump lubrication system 36
- Accessories 37
- Air supply kit 37
- Circulation kit 37
- Conversion kit 37
- Data reporting kit 37
- Feed pump kits 37
- Fusion spray gun 37
- Heated hoses 37
- Heated whip hoses 37
- Return tube kit 37
- Dimensions 38
- Electric reactor proportioning system 39
- Technical specifications 39
- Electric reactor proportioning system 40
- California proposition 65 41
- California residents 41
- Warning cancer and reproductive harm www p65warnings ca gov 41
- For the latest information about graco products visit www graco com for patent information see www graco com patents to place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505 42
- Graco headquarters minneapolis international offices belgium china japan korea 42
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa copyright 2020 graco inc all graco manufacturing locations are registered to iso 9001 42
- Graco information 42
- Graco standard warranty 42
- June 2020 42
- Www graco com revision 42
Похожие устройства
- Graco Reactor E-20 P29025 Брошюра
- Graco Reactor E-20 P29025 Сертификат
- Graco Reactor E-20 P29025 Техническая документация
- Graco Reactor E-20 P29030 Инструкция по эксплуатации
- Graco Reactor E-20 P29030 Брошюра
- Graco Reactor E-20 P29030 Сертификат
- Graco Reactor E-20 P29030 Техническая документация
- Graco Reactor E-20 P29034 Инструкция по эксплуатации
- Graco Reactor E-20 P29034 Брошюра
- Graco Reactor E-20 P29034 Сертификат
- Graco Reactor E-20 P29034 Техническая документация
- Graco Reactor E-20 PH9025 Инструкция по эксплуатации
- Graco Reactor E-20 PH9025 Брошюра
- Graco Reactor E-20 PH9025 Сертификат
- Graco Reactor E-20 PH9025 Техническая документация
- Graco Reactor E-20 PH9030 Инструкция по эксплуатации
- Graco Reactor E-20 PH9030 Брошюра
- Graco Reactor E-20 PH9030 Сертификат
- Graco Reactor E-20 PH9030 Техническая документация
- Graco Reactor E-20 PH9034 Инструкция по эксплуатации