Graco Reactor 3 E-20 ESR311 [7/36] Keep components a and b separate
![Graco Reactor 3 E-20 26R312 [7/36] Keep components a and b separate](/views2/1900372/page7/bg7.png)
Important Isocyanate (ISO) Information
309577Y 7
Keep Components A and B
Separate
Moisture Sensitivity of
Isocyanates
Exposure to moisture (such as humidity) will cause ISO
to partially cure, forming small, hard, abrasive crystal
that become suspended in the fluid. Eventually a film
will form on the surface and the ISO will begin to gel,
increasing in viscosity.
NOTE: The amount of film formation and rate of
crystallization varies depending on the blend of ISO, the
humidity, and the temperature.
Foam Resins with 245 fa
Blowing Agents
Some foam blowing agents will froth at temperatures
above 90°F (33°C) when not under pressure, especially
if agitated. To reduce frothing, minimize preheating in a
circulation system.
Changing Materials
Cross-contamination can result in cured material in
fluid lines which could cause serious injury or
damage equipment. To prevent cross-contamination:
• Never interchange component A and component
B wetted parts.
• Never use solvent on one side if it has been
contaminated from the other side.
NOTICE
Partially cured ISO will reduce performance and the life
of all wetted parts.
• Always use a sealed container with a desiccant
dryer in the vent, or a nitrogen atmosphere. Never
store ISO in an open container.
• Keep the ISO pump wet cup or reservoir (if
installed) filled with appropriate lubricant. The
lubricant creates a barrier between the ISO and
the atmosphere.
• Use only moisture-proof hoses compatible with
ISO.
• Never use reclaimed solvents, which may contain
moisture. Always keep solvent containers closed
when not in use.
• Always lubricate threaded parts with an
appropriate lubricant when reassembling.
NOTICE
Changing the material types used in your equipment
requires special attention to avoid equipment damage
and downtime.
• When changing materials, flush the equipment
multiple times to ensure it is thoroughly clean.
• Always clean the fluid inlet strainers after flushing.
• Check with your material manufacturer for
chemical compatibility.
• When changing between epoxies and urethanes
or polyureas, disassemble and clean all fluid
components and change hoses. Epoxies often
have amines on the B (hardener) side. Polyureas
often have amines on the B (resin) side.
Содержание
- Air and electric proportioners for professional use only 1
- Displacement pump 1
- For use with reacto 1
- Important safety instructions 1
- Instructions 1
- Contents 2
- Model numbers 2
- Related manuals 2
- Warning 3
- Warnings 3
- Warning 4
- Warning 5
- Important isocyanate iso information 6
- Isocyanate conditions 6
- Changing materials 7
- Foam resins with 245 fa blowing agents 7
- Keep components a and b separate 7
- Moisture sensitivity of isocyanates 7
- Pressure relief procedure 8
- Repair 8
- Clean and inspect parts 9
- Fill the wet cups 9
- Repair kits 9
- Tools needed 9
- Component a iso pump 10
- Cutaway views 10
- 245972 18d010 11
- 262648 24y174 11
- Component b resin pump 11
- Disassemble the pump 12
- Reassemble the pump 15
- Component a iso pumps with wet cup flush feature 20
- Component b resin pumps 28
- Note these pumps were also used on component a iso side of reactors built before may 2003 28
- Part 245970 e 20 and e xp1 includes items 1 7 9 23 part 245971 e xp2 includes items 1 7 9 22 part 262648 a 25 includes items 1 7 9 22 part 245972 e 30 includes items 1 22 shown part 24y174 a xp1 includes items 1 7 9 22 part 18d010 reactor 3 e 20 includes items 1 17 19 22 28
- Parts included in pump repair kits purchase separately some parts in the kit may not be used in your pump order the correct kit for your pump from the table below 30
- Pump part repair kit 245970 246420 245971 262648 246421 245972 246422 24y174 17k352 18d010 18e196 30
- Wet cup conversion kits may be purchased separately to convert pumps 245970 245971 262648 and 245972 see page 33 for further information 30
- Accessories 33
- Iso pump oil 33
- Reservoir kit 33
- Throat seal liquid 33
- Wet cup conversion kits 33
- Displacement pump 34
- Technical specifications 34
- California proposition 65 35
- California residents 35
- Warning cancer and reproductive harm www p65warnings ca gov 35
- For the latest information about graco products visit www graco com for patent information see www graco com patents 36
- Graco headquarters minneapolis international offices belgium china japan korea 36
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa copyright 2003 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revision 36
- Graco information 36
- Graco standard warranty 36
- March 2022 36
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505 36
Похожие устройства
- Graco Reactor 3 E-20 ESR312 Инструкция по эксплуатации
- Graco Reactor 3 E-20 ESR312 Брошюра
- Graco Reactor 3 E-20 ESR312 Сертификат
- Graco Reactor 3 E-20 ESR312 Техническая документация
- Graco Reactor 3 E-20 ESR313 Инструкция по эксплуатации
- Graco Reactor 3 E-20 ESR313 Брошюра
- Graco Reactor 3 E-20 ESR313 Сертификат
- Graco Reactor 3 E-20 ESR313 Техническая документация
- Graco Reactor 3 E-20 IHR310 Инструкция по эксплуатации
- Graco Reactor 3 E-20 IHR310 Брошюра
- Graco Reactor 3 E-20 IHR310 Сертификат
- Graco Reactor 3 E-20 IHR310 Техническая документация
- Graco Reactor 3 E-20 IHR311 Инструкция по эксплуатации
- Graco Reactor 3 E-20 IHR311 Брошюра
- Graco Reactor 3 E-20 IHR311 Сертификат
- Graco Reactor 3 E-20 IHR311 Техническая документация
- Graco Reactor 3 E-20 IHR312 Инструкция по эксплуатации
- Graco Reactor 3 E-20 IHR312 Брошюра
- Graco Reactor 3 E-20 IHR312 Сертификат
- Graco Reactor 3 E-20 IHR312 Техническая документация