10 3A7683G
Installation
Grounding
Whip Hose
Hose core is statically conductive
Internally Heated Main Hose
Hose core is statically conductive
Externally Heated Main Hose
Grounded through conductive air line
NOTE: To effectively dissipate static, the entire
grounding path from proportioner to gun must be less
than 29 megohms.
Reactor 3 heated hoses are designed for use only
with Graco Reactor 3 proportioners.
To reduce the risk of fire and serious injury, never
connect these hoses to any other device.
This equipment is used with heated fluid, which can
cause equipment surfaces to become very hot. To
avoid severe burns:
Do not touch hot fluid or equipment.
Do not turn on hose heat without fluid in hoses.
Allow equipment to cool completely before
touching it
Wear gloves if fluid temperature exceeds 110°F
(43°C).
NOTICE
Incorrect connection of fittings can cause fluid
crossover and permanently damage the hose.
Fittings have different sized threads to prevent
incorrect connection. Only connect fittings with
matching thread sizes.
NOTICE
Heated hose must always contain fluid when hose
power is on. Never apply power to an empty heated
hose. Powering empty hoses may cause equipment
damage.
NOTICE
Always completely unroll and bleed the air from the
hose before each use. If the air is not bled from the
hose, heat transfer from the heating conductor will
not be uniform. In the worst case, the heating
element can be damaged. The warranty is void in
such cases.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.