Graco REACTOR 3 E-30 ISR333 [47/64] Setup screens

Graco REACTOR 3 E-30 ISR333 [47/64] Setup screens
AdvanceDisplayModule(ADM)
Setup Setup
Setup
Screens Screens
Screens
UsetheSetupscreensscreenstoeditsettings
fortheReactorsystem.
Pressure/Flow Pressure/Flow
Pressure/Flow
UsethePressure/Flowscreentosetpressure
monitoringsettingsfortheReactorsystem.
Setting Setting
Setting
Description Description
Description
EnableAuto
PressureBalance
Thisfeaturemonitorsthepressure
imbalancewhilematerialisowing
andaddstemperatureoffsetstothe
setpointstominimizethepressure
imbalance.
Tapthecheckboxtoenable/disable
AutoPressureBalance.Tap
thenumbervaluetoadjustthe
temperatureoffsetlimitallowed
usingAutoPressureBalance.
NOTE: NOTE:
NOTE:
Thisfeatureisonlyenabled
onProandElitemodels.
EnablePressure
ImbalanceAlarms
Tapthecheckboxtoenable/disable
PressureImbalanceAlarms.Tapthe
numbervaluetoadjustthealarm
threshold.
NOTE: NOTE:
NOTE:
Pressureimbalancealarmsare
automaticallyenablesifowmeters
areenabled.
EnablePressure
Imbalance
Deviations
Tapthecheckboxtoenable/disable
PressureImbalanceDeviations.Tap
thenumbervaluetoadjustthe
deviationthreshold.
EnableReactor
SmartControl
Tapthecheckboxtoenable/disable
ReactorSmartControl.Thisfeature
doesthefollowing:
Slowsdowntheproportionerpump
ifinletpressureislow.Thisis
donetoallowthetransferpumps
tokeepupandavoidoff-ratio
conditions.
Controlstheoutputpressuretothe
averageoftheAandBpressure
sensors(insteadofthemax).
EnableFlow
Meters
Tapthecheckboxtoenable/disable
owmeters.
EnableFlowMeter
Alarms
Tapthecheckboxtoenable/disable
owmeteralarms.Tapthenumber
valuetoadjustthealarmthreshold.
NOTE: NOTE:
NOTE:
Flowmeteralarmsareonly
availablewhenowmetersare
installed.
FlowMeterA
K-Factor
Tapthenumbervaluetoenterthe
K-FactorfortheAsideowmeter.
NOTE: NOTE:
NOTE:
TheK-Factorisnotedonthe
meterlabel.
FlowMeterB
K-Factor
Tapthenumbervaluetoenterthe
K-FactorfortheBsideowmeter.
NOTE: NOTE:
NOTE:
TheK-Factorisnotedonthe
meterlabel.
EnableMaximum
PressureSetpoint
Tapthecheckboxtoenable/disable
auserdenedmaximumpressure
setpoint.Tapthenumbertoadjust
themaximumpressuresetpointthat
canbeenteredonthehomescreen.
EnableMinimum
PressureSetpoint
Tapthecheckboxtoenable/disable
auserdenedminimumpressure
setpoint.Tapthenumbertoadjust
theminimumpressuresetpointthat
canbeenteredonthehomescreen.
EnableJogLimitTapthecheckboxtoenable/disable
thejoglimitfeature.Tapthenumber
toadjustthejogcyclelimit.When
enabledandinjogmode,theReactor
pumpwillautomaticallyshutoff
whenthespeciednumberofcycles
arecompleted.
NOTE:Thisfeaturecanbeenabled
directlyonthehomescreen.