Installation
309572ZAT 19
Connect FTS with a Non-Heated Whip Hose or Remote Mix
Manifold
1. Carefully extend FTS probe (H) into the hose
section from the proportioner. Do not bend or kink
probe. Insert probe in major volume (resin) side
on systems which are not 1:1 mix ratio.
2. Connect FTS (5) to mating assembly.
3. Connect fluid hoses to FTS.
NOTE: To use 1/2 in. (13 mm) ID fluid hoses, remove
the adapters from the proportioner fluid manifold and
install them in the FTS swivel inlets.
4. Install one connector (12) between wires. Refer to
page 13 for instructions.
5. Connect hose assembly cable (4) to FTS cable (part
of 5). Slide insulator sleeves (S) over connection.
Leave slack in cables as stress relief, to prevent
cable failure.
6. Connect appropriate ground wire.
7. See Connect Hoses to Proportioner, page 20.
NOTICE
To prevent damage to probe, do not kink or
excessively bend hose. Do not coil hose tighter than
the minimum bend radius of 1.5 ft (0.5 m). Do not
subject hose to excessive weight, impact, or other
abuse.
5
S
H
TI2684E
S
4
To Mix Manifold or
non-heated whip hose
To Proportioner
12