Comprag А3713 [18/92] Version 5

Comprag А3010 [18/92] Version 5
18
Version 5.2
The main parameters of the compressor are displayed after 5 seconds:
21°C 0.00HZ
0.0BAR 0RPM
STOP
C01 LOKAL
Main menu: Click in order to bring up the options menu:
RUN PARAMETERS Includes current values (available for viewing)
USAGE PARAM
Includes operating settings of the main parameters (available for viewing,
changes password-protected)
FACTORY PARAM For servicing mode (view with password). Modication only possible by manufacturer
ADJUST. PARAM Basic settings and maintenance hour counter (Password protected)
Description of the parameters. Run parameters:
Select the run parameters using the up and down buttons and enter . Current values
are displayed.
M1 AND FAN CUR
TOTAL RUN TIME
THIS RUN TIME
MAINTEN. PARAM
ERRORS HISTORY
SERIAL NUMBER
THIS ERROR
COM. STATUS
The other menus have a similar structure.
Select the line “ M1 AND FAN CUR ” and press
.
M1(A) AND FAN(A)
A: 000.0 000.0
B: 0.0 0.0
C:0.0 0.0
Phase current of main motor and fan motor
TOTAL RUN TIME
TOTAL RUN TIME: Total running hours (main engine running).
TOTAL LOAD TIME: Total operating time under load (main engine running+ suction valve open).
THIS RUN TIM
THIS RUN TIME: The current operating time from the last start.
THIS LOAD TIME: Current running time under load