Comprag А3713 [24/92] Maintenance

Comprag А3010 [24/92] Maintenance
24
Version 5.2
5. Maintenance
5.1 Maintenance schedule
Maintenance schedule
Daily Monthly Yearly
Interval in work hours
M-1 M-2 M-3 M-2
500 2000 4000 6000
Oil level Check/
Rell
Compressor oil Replace Replace Replace Replace
Air lter Cleaning Replace Replace Replace
Oil lter Replace Replace Replace Replace
Ait-Oil Separator Replace
Drive belt Check
Heat exchanger Cleaning
Bearings of electric
motor
Lubricate
Intake valve Check
Minimum pressure
valve
Check
Safety valve Check
Beyond 6000 working hours, compressor maintenance consists in alternating M-2 and M-3
every 2000 hours of running time. Performance of daily, weekly, monthly and annual servic-
ing does not annul the need for maintenance in terms of operating hours.
5.2 Checking oil level
Check oil level on a daily basis. In order to access the oil level, stop the compressor and
remove the front side panel.
The oil level in the compressor should be checked visually with the oil level glass (1) when
the compressor has stopped.
The surface of the oil must always be visible in the sight glass.
If no oil is visible in the sight glass, the oil level is low and needs to be topped up. Using belt
tension gauge, check the tensile force of the compressor belts.