INSTALLATION
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use,a minimum of 5 cm space shall be preserved around
the hole.
Be sure the thickness of the work surface is at least 30 mm.Please select heat-resistant
work surface material to avoid larger deformation caused by the heat radiation from the
hotplate. As shown below:
MODEL: MHI 3002
Д (mm) Ш (mm) В (mm) D(mm) A(mm) B(mm) X(mm)
290 520 60 56 260 490 50 mini
Д (mm) Ш (mm) В (mm) D(mm) A(mm) B(mm) X(mm)
590 520 52 48 560 490 50 mini
MODEL: MHE 6002 / MHE 6022
Д (mm) Ш (mm) В (mm) D(mm) A(mm) B(mm) X(mm)
290 520 52 48 265 500 50 mini
MODEL: MHE 3002
Under any circumstances,make sure the ceramic cooker hob is well ventilated and the air
inlet and outlet are not blocked.Ensure the ceramic cooker hob is in good work state. As shown
below
Note: The safety distance between the hotplate and the cupboard above the hotplate
should be at least 650 mm.