Sencor SFH 9012 [4/6] Ceramic heater

CERAMIC HEATER SFH 9012 side At the same time the relevant indicator will be on By pressing the sensor again the turning function will be turned off and the relevant indicator will turn off Do not set the direction of air flow by turning the body of the device by force relative to the base of the device If the direction of air flow does not suit you hold the device by the hadle and turn the entire device including the base according to your requirements Make sure not to entangle the power cord Touch sensor 0 setting the timed shut off This function serves to automatically turn off the device after duration of the set time While the device is in operation touch the sensor marked with the symbol Q and the device will switch into timer setting mode The automatic shut off timer may be set in the range from 00 30 to 07 30 With each press of the button the time will be extended by half an hour At the same time the set time will be displayed on the display The device will automatically shut off after the duration of the set time REMOTE CONTROL Open the battery cover on the back side of the remote control Insert 2 alkaline AAA 2 x LR03 2 x 1 5 V batteries When inserting the batteries ensure that their polarity is correct There are 4 buttons on the remote control and their functions are the same as those on the control panel If you wish to use the remote control point the remote control at approximately the level of the control panel with the display The maximum signal range of the remote control is 6 m If you place the remote control in such a way that the signal is blocked by barriers the signal may not be transmitted at all The safety function of the automatic shut off when the device overheats If you tilt the device you will hear a click sound This is due to the in built safety device which serves to automatically turn off the device when it is tilted If the during operation the device is tilted by approx 45 the safety function is activated and the device will shut off If the device falls over then this function serves as protection against the creation of a dangerous situation Double heat fuse The device is equipped with a resetable heat fuse which is activated and shuts off the device if it overheats If such a situation occurs disconnect the device from the el power socket As soon as the device cools down connect it to the power socket and you may turn it on again To increase safety the device is equipped with a non resetable heat fuse for the situation where the first heat fuse malfunctions If the non resetable heat fuse has been activated operation cannot be resumed Have the device repaired at an authorised service centre EN 4 Copyright 2012 Fast CR a s Revision 05 2012

Скачать
Случайные обсуждения

Ответы 0

как включить вентилятор без нагрева
11 месяцев назад