Timberk T-AC09-S29 [6/52] The outdoor unit shall be installed as far as possible from the doors and windows of the
![Timberk T-AC09-S29 [6/52] The outdoor unit shall be installed as far as possible from the doors and windows of the](/views2/1936411/page6/bg6.png)
IM2020
6
temperature range:
heating
Filling of refrigerant
g
400
540
610
1000
1450
Distance between
brackets (outdoor
unit)
mm
431*278
431*278
500*260
546*300
540*335
Service area of the
device
m
2
up to 22
up to 25
up to 35
up to 50
up to 70
Annual energy
consumption
(cooling mode)
kW*h/yea
r
343
420
593
923
1211
Operating mode
(cooling/cooling +
heating)
-
cooling + heating
cooling + heating
cooling + heating
cooling + heating
cooling + heating
Cooling type
(air/water)
-
air
air
air
air
air
Compressor
-
Toshiba
Toshiba
Toshiba
Hitachi
Hitachi
Maximum operating
pressure
of refrigerant circuit
(discharge/suction)
MPa
4.15/1.15
4.15/1.15
4.15/1.15
4.15/1.15
4.15/1.15
Net weight (indoor
unit)
kg
8
8.5
8
11
12
Net weight (outdoor
unit)
kg
20
21
26
35
39
Gross weight
(indoor unit)
kg
9.5
10
10.5
13
14
Gross weight
(outdoor unit)
kg
22
23
27.5
40
43
Net dimensions
(indoor unit)
mm
690×283×199
690×283×199
750×285×200
900×310×225
900×310×225
Net dimensions
(outdoor unit)
mm
665×420×280
665×420×280
660×500×240
800×545×315
825×655×310
Packing dimensions
(indoor unit)
mm
760×345×280
760×345×280
820×345×280
970×380×305
970×380×305
Packing dimensions
(outdoor unit)
mm
760×470×345
760×470×345
780×550×345
920×605×395
945×435×725
8. INSTALLATION OF THE DEVICE
Important Notices:
Before installing, please contact with local authorized maintenance center, if unit is not
installed by the authorized maintenance center, the malfunction may not be solved, due to
discommodious contact. To move and install air conditioner to another place, also please
contact our local special service center.
The air conditioner must be installed by professionals according to the national wiring rules
and this manual.
Requirements for Installation position:
Avoid places of inflammable or explosive gas leakage or where there are strongly
aggressive gases.
Avoid places subject to strong artificial electric/magnetic fields.
Avoid places subject to noise and resonance.
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine
or high temperature heat sources).
Avoid places within the reach of children.
Select where it is easy to perform service and repair and where the ventilation good.
The outdoor unit shall not be installed in any way that could occupy an aisle, stairway, exit,
fire escape, catwalk or any other public area.
The outdoor unit shall be installed as far as possible from the doors and windows of the
Содержание
- Instruction manual руководство по эксплуатации p.1
- Модели models p.1
- Technical specifications of the device are indicated in table 2 table 2 p.5
- Technical specifications p.5
- Specifications p.5
- Im2020 p.5
- Delivery set p.5
- Conditioner unit for indoor installation 1 piece conditioner unit for indoor installation 1 piece conditioner unit for outdoor installation 1 piece remote control 1 piece batteries for remote control aaa 2 pieces user manual 1 piece warranty card 1 piece packing of indoor installation unit 1 piece packing of outdoor installation unit 1 piece p.5
- Complete set of air conditioner split system includes p.5
- Avoid places within the reach of children p.6
- Avoid places subject to strong artificial electric magnetic fields p.6
- Avoid places subject to noise and resonance p.6
- Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases p.6
- The outdoor unit shall not be installed in any way that could occupy an aisle stairway exit fire escape catwalk or any other public area p.6
- The outdoor unit shall be installed as far as possible from the doors and windows of the p.6
- The air conditioner must be installed by professionals according to the national wiring rules and this manual p.6
- Select where it is easy to perform service and repair and where the ventilation good p.6
- Requirements for installation position p.6
- Installation of the device p.6
- Important notices p.6
- Im2020 p.6
- Before installing please contact with local authorized maintenance center if unit is not installed by the authorized maintenance center the malfunction may not be solved due to discommodious contact to move and install air conditioner to another place also please contact our local special service center p.6
- Avoid severe natural conditions e g heavy lampblack strong sandy wind direct sunshine or high temperature heat sources p.6
- Технические характеристики p.30
- Рабочие характеристики p.30
- Комплект поставки p.30
- В комплектацию кондиционера воздуха сплит системы входит p.30
- Блок кондиционера для внутренней установки 1 шт блок кондиционера для внутренней установки 1 шт блок кондиционера для наружной установки 1 шт пульт дистанционного управления 1 шт элементы питания для пульта ду ааа 2 шт руководство по эксплуатации 1 шт гарантийный талон 1 шт упаковка блока внутренней установки 1 шт упаковка блока наружной установки 1 шт p.30
- Im2020 p.30
- Технические характеристики прибора приведены в таблице 2 таблица 2 p.30
- Установленный внешний блок не должен занимать пространство в таких местах как коридоры лестницы выходы пожарные выходы или другие места публичного пользования p.31
- Требования к пространству для установки требования к пространству для установки при выборе пространства для установки p.31
- Прибор должен быть установлен профессионалом согласно данному руководству и в соответствии с национальными правилами монтажа электроустановок p.31
- Перед установкой перемещением и повторным монтажом пожалуйста обратитесь в авторизованный сервисный центр p.31
- Монтаж прибора p.31
- Избегайте мест с суровыми условиями окружающей среды сильная копоть сильные ветра с песком сильный прямой солнечный свет источники тепла высокой температуры p.31
- Избегайте мест с сильным электромагнитным излучением p.31
- Избегайте мест с высоким уровнем шума и или вибрации p.31
- Избегайте мест где прибор будет доступен детям p.31
- Избегайте мест возможной протечки газа не устанавливайте кондиционер рядом с приборами работающими на газовом топливе и рядом с газопроводами p.31
- Выберите место в котором будут удобны сервисное обслуживание и ремонт а также хорошая вентиляция p.31
- Важная информация p.31
- Im2020 p.31
- T ac24 s29 y p.46
- T ac07 s29 y t ac09 s29 y t ac12 s29 y t ac18 s29 y p.46
- Принципиальные электрические схемы p.46
- T ac24 s29 x t ac24 s29 x p.47
- T ac07 s29 x t ac09 s29 x t ac12 s29 x t ac18 s29 x p.47
- Руководство по эксплуатации p.52
- Www timberk ru p.52
Похожие устройства
-
Timberk T-AC24-S29Руководство по эксплуатации -
Timberk T-AC24-S28Руководство по эксплуатации -
Timberk T-AC24-S27Руководство по эксплуатации -
Timberk T-AC24-S25Руководство по эксплуатации -
Timberk T-AC18-S29Руководство по эксплуатации -
Timberk T-AC18-S28Руководство по эксплуатации -
Timberk T-AC18-S27Руководство по эксплуатации -
Timberk T-AC18-S25Руководство по эксплуатации -
Timberk T-AC12-S29Руководство по эксплуатации -
Timberk T-AC12-S27Руководство по эксплуатации -
Timberk T-AC12-S25Руководство по эксплуатации -
Timberk T-AC09-S27Руководство по эксплуатации