Timberk T-AC18-S29 [6/52] The outdoor unit shall not be installed in any way that could occupy an aisle stairway exit fire escape catwalk or any other public area
![Timberk T-AC07-S29 [6/52] The outdoor unit shall not be installed in any way that could occupy an aisle stairway exit fire escape catwalk or any other public area](/views2/1936411/page6/bg6.png)
IM2020
6
temperature range:
heating
Filling of refrigerant
g
400
540
610
1000
1450
Distance between
brackets (outdoor
unit)
mm
431*278
431*278
500*260
546*300
540*335
Service area of the
device
m
2
up to 22
up to 25
up to 35
up to 50
up to 70
Annual energy
consumption
(cooling mode)
kW*h/yea
r
343
420
593
923
1211
Operating mode
(cooling/cooling +
heating)
-
cooling + heating
cooling + heating
cooling + heating
cooling + heating
cooling + heating
Cooling type
(air/water)
-
air
air
air
air
air
Compressor
-
Toshiba
Toshiba
Toshiba
Hitachi
Hitachi
Maximum operating
pressure
of refrigerant circuit
(discharge/suction)
MPa
4.15/1.15
4.15/1.15
4.15/1.15
4.15/1.15
4.15/1.15
Net weight (indoor
unit)
kg
8
8.5
8
11
12
Net weight (outdoor
unit)
kg
20
21
26
35
39
Gross weight
(indoor unit)
kg
9.5
10
10.5
13
14
Gross weight
(outdoor unit)
kg
22
23
27.5
40
43
Net dimensions
(indoor unit)
mm
690×283×199
690×283×199
750×285×200
900×310×225
900×310×225
Net dimensions
(outdoor unit)
mm
665×420×280
665×420×280
660×500×240
800×545×315
825×655×310
Packing dimensions
(indoor unit)
mm
760×345×280
760×345×280
820×345×280
970×380×305
970×380×305
Packing dimensions
(outdoor unit)
mm
760×470×345
760×470×345
780×550×345
920×605×395
945×435×725
8. INSTALLATION OF THE DEVICE
Important Notices:
Before installing, please contact with local authorized maintenance center, if unit is not
installed by the authorized maintenance center, the malfunction may not be solved, due to
discommodious contact. To move and install air conditioner to another place, also please
contact our local special service center.
The air conditioner must be installed by professionals according to the national wiring rules
and this manual.
Requirements for Installation position:
Avoid places of inflammable or explosive gas leakage or where there are strongly
aggressive gases.
Avoid places subject to strong artificial electric/magnetic fields.
Avoid places subject to noise and resonance.
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine
or high temperature heat sources).
Avoid places within the reach of children.
Select where it is easy to perform service and repair and where the ventilation good.
The outdoor unit shall not be installed in any way that could occupy an aisle, stairway, exit,
fire escape, catwalk or any other public area.
The outdoor unit shall be installed as far as possible from the doors and windows of the
Содержание
- Instruction manual руководство по эксплуатации 1
- Модели models 1
- Complete set of air conditioner split system includes 5
- Conditioner unit for indoor installation 1 piece conditioner unit for indoor installation 1 piece conditioner unit for outdoor installation 1 piece remote control 1 piece batteries for remote control aaa 2 pieces user manual 1 piece warranty card 1 piece packing of indoor installation unit 1 piece packing of outdoor installation unit 1 piece 5
- Delivery set 5
- Im2020 5
- Specifications 5
- Technical specifications 5
- Technical specifications of the device are indicated in table 2 table 2 5
- Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases 6
- Avoid places subject to noise and resonance 6
- Avoid places subject to strong artificial electric magnetic fields 6
- Avoid places within the reach of children 6
- Avoid severe natural conditions e g heavy lampblack strong sandy wind direct sunshine or high temperature heat sources 6
- Before installing please contact with local authorized maintenance center if unit is not installed by the authorized maintenance center the malfunction may not be solved due to discommodious contact to move and install air conditioner to another place also please contact our local special service center 6
- Im2020 6
- Important notices 6
- Installation of the device 6
- Requirements for installation position 6
- Select where it is easy to perform service and repair and where the ventilation good 6
- The air conditioner must be installed by professionals according to the national wiring rules and this manual 6
- The outdoor unit shall be installed as far as possible from the doors and windows of the 6
- The outdoor unit shall not be installed in any way that could occupy an aisle stairway exit fire escape catwalk or any other public area 6
- Im2020 30
- Блок кондиционера для внутренней установки 1 шт блок кондиционера для внутренней установки 1 шт блок кондиционера для наружной установки 1 шт пульт дистанционного управления 1 шт элементы питания для пульта ду ааа 2 шт руководство по эксплуатации 1 шт гарантийный талон 1 шт упаковка блока внутренней установки 1 шт упаковка блока наружной установки 1 шт 30
- В комплектацию кондиционера воздуха сплит системы входит 30
- Комплект поставки 30
- Рабочие характеристики 30
- Технические характеристики 30
- Технические характеристики прибора приведены в таблице 2 таблица 2 30
- Im2020 31
- Важная информация 31
- Выберите место в котором будут удобны сервисное обслуживание и ремонт а также хорошая вентиляция 31
- Избегайте мест возможной протечки газа не устанавливайте кондиционер рядом с приборами работающими на газовом топливе и рядом с газопроводами 31
- Избегайте мест где прибор будет доступен детям 31
- Избегайте мест с высоким уровнем шума и или вибрации 31
- Избегайте мест с сильным электромагнитным излучением 31
- Избегайте мест с суровыми условиями окружающей среды сильная копоть сильные ветра с песком сильный прямой солнечный свет источники тепла высокой температуры 31
- Монтаж прибора 31
- Перед установкой перемещением и повторным монтажом пожалуйста обратитесь в авторизованный сервисный центр 31
- Прибор должен быть установлен профессионалом согласно данному руководству и в соответствии с национальными правилами монтажа электроустановок 31
- Требования к пространству для установки требования к пространству для установки при выборе пространства для установки 31
- Установленный внешний блок не должен занимать пространство в таких местах как коридоры лестницы выходы пожарные выходы или другие места публичного пользования 31
- T ac07 s29 y t ac09 s29 y t ac12 s29 y t ac18 s29 y 46
- T ac24 s29 y 46
- Принципиальные электрические схемы 46
- T ac07 s29 x t ac09 s29 x t ac12 s29 x t ac18 s29 x 47
- T ac24 s29 x t ac24 s29 x 47
- Www timberk ru 52
- Руководство по эксплуатации 52
Похожие устройства
- Timberk T-AC24-S25 Руководство по эксплуатации
- Timberk T-AC24-S27 Руководство по эксплуатации
- Timberk T-AC24-S28 Руководство по эксплуатации
- Timberk T-AC24-S29 Руководство по эксплуатации
- Whirlpool AMD 012(1) Руководство по эксплуатации
- Whirlpool AMD 030 Руководство по эксплуатации
- Whirlpool AMD 039 Руководство по эксплуатации
- Whirlpool AMD 301 Руководство по эксплуатации
- Ariston BS II 24 CF (FF) Инструкция по эксплуатации
- Ariston CLAS 24 CF (FF) Руководство по эксплуатации
- Ariston CLAS B 24 CF (FF) Руководство по эксплуатации
- Ariston CLAS SYSTEM 15 CF (FF) Руководство по эксплуатации
- Ariston CLAS SYSTEM 24 CF (FF) Руководство по эксплуатации
- Ariston CLAS SYSTEM 28 CF (FF) Руководство по эксплуатации
- Ariston EGIS PLUS 24 CF (FF) Инструкция по эксплуатации
- Ariston GENUS 24 CF (FF) Руководство по эксплуатации
- Ariston GENUS 28 CF (FF) Руководство по эксплуатации
- Ariston GENUS PREMIUM HP 100 Инструкция по эксплуатации
- Ariston GENUS PREMIUM HP 45 Инструкция по эксплуатации
- Ariston GENUS PREMIUM HP 65 Инструкция по эксплуатации