Timberk THU UL 25 [6/24] Transportation and storage

Timberk THU UL 25 [6/24] Transportation and storage
www.timberk.com • electric humidifier
6
9. TROUBLESHOOTING
• Always unplug the unit before removing the water tank.
• Do not touch the water in the base during operation!
• Caution-risk of electric shock and damage of the product!
• Switch off the appliance and unplug it from the socket before cleaning it.
Clean the water tank and the base regularly. Use water only, no detergents.
10. TRANSPORTATION AND STORAGE
1. When transporting, any possible impacts and movements of the
package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when
transporting and storing it.
3.
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
-30°C to +50°C
15% to 85%
(no condensate)
We are researching new technologies and constantly improving the quality
of our products. Specifications, design and scope of delivery may be
changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C.
Service life of the humidifier is 2 years.
At the end of its service life the humidifier should be utilized in accordance
with regulations and procedures, which are in force at the place of utilization.
11. DISPOSAL
Problem Possible cause Remedy
Poor atomizing (insufficient
capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need to switch
to the intensive mode of operation, turn the
regulator handle all the way to the right.
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank is too low
Set maximum capacity. The humidifier’s
capacity will go up after a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the outlet
carefully
There is white deposit on objects
around the humidifier (salts,
separating out from water)
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water used
(calcium and magnesium)
1. Clean the humidifier’s membrane with a
special brush
2. Use filtered water
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the cleaning
and servicing instructions and fill the tank
with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or the
atomizer
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and temperature.
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water (in
the unit’s base).
1. Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
2. Clean the unit according to the cleaning
and servicing instructions.
Water appears next to the humidifier,
when it is not operating
Water tank is leaking
You need to contact an authorized service
center

Содержание