Philips FC8236 [9/116] Replacing the dustbag

Philips FC8236 [9/116] Replacing the dustbag
Make sure you hold the dustbag upright when you lift it out of the appliance.
4 Pull the motor protection lter holder forwards to release it (Fig. 18).
5 Remove the motor protection lter from lter holder.
6 Shake the motor protection lter over a dustbin to clean it.
7 Put the clean lter back into the lter holder.
8 Fit the two lugs at the bottom of the lter holder into the brackets (1). Then press the lter
holder home (‘click’) (2). (Fig. 19)
9 Place the bottom edge of the dustbag in front of the ridge on the bottom of the appliance
(1). Pull the cardboard front of the dustbag towards you (‘click’) (2). (Fig. 20)
Note: If no dustbag has been inserted, you cannot close the cover.
10 Close the cover.


Tip: We advise you to clean the motor protection lter every time you replace the dustbag (see chapter
‘Cleaning’).
Always unplug the appliance before you replace the dustbag.

In some cases, the dustbag-full indicator can indicate that the dustbag is full, even though it is not.
This may occur if the pores of the dustbag are clogged (e.g. when you have vacuumed ashes, ne
sand, lime, cement dust and similar substances) or if something is blocking the nozzle, tube and/or
hose. If the pores of the dustbag are clogged, you have to replace the dustbag, even if it is not full
yet. If the dustbag is not clogged but not full either, something is blocking the nozzle, tube and/or
hose. In this case, do not replace the dustbag but remove the obstruction.

- Replace the dustbag as soon as the dustbag-full indicator has changed colour permanently, i.e.
even when the nozzle is not placed on the oor (Fig. 21).
1 Pull at the cover release tab (1) and open the cover (2) (Fig. 15).
2 Pull the clamps aside (1) and pull the dustbag forward (2) (Fig. 16).
3 Pull the cardboard tag upwards to lift the dustbag out of the appliance. (Fig. 17)
, The dustbag is sealed automatically.
4 Place the bottom edge of the new dustbag in front of the ridge on the bottom of the
appliance (1). Pull the cardboard front of the dustbag towards you (‘click’) (2) (Fig. 22).
Note: If no dustbag has been inserted, you cannot close the cover.
5 Close the cover.

Your vacuum cleaner is equipped with a Clean Air HEPA outlet lter (service code 4222 459
48841).
Replace the Clean Air HEPA outlet lter every 12 months.
1 Switch off and unplug the appliance.
2 Pull at the grip on the lter grille (1) and remove it from the appliance (2) (Fig. 23).