Oleo-Mac PW 155 [24/136] Caution

Oleo-Mac PW 155 [24/136] Caution
24
7 CleanInG and maIntenanCe
WARNING
Only start cleaning and maintenance once the instructions in the “Switching off” section have been completed.
It is particularly important to always disconnect the electricity supply.
To safeguard the safety of the high pressure cleaner, only use the original spare parts supplied by the Manufacturer
or those endorsed by him.
The rubber pipes, the coupling and the high-pressure lances are important for safety: only use those endorsed by
the Manufacturer.
7.1 routIne maIntenanCe
Follow the instructions in the “Switching off” section and abide by the recommendations in the table below.
INTERVAL FOR MAINTENANCE ACTION
Each time used • Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance
pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
Weekly • Clean the water inlet lter (26).
Usually, it is sufcient to pass the lter under running water or in a jet of
compressed air to clean it. In more difcult cases, use a lime scale remover or
replace the lter. Contact an authorised service centre for the purchase of a
new lter.
Monthly • Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the
nozzle hole. In case you do not obtain any appreciable result, apply to an
authorised service centre.
CAUTION
During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should not drip
from underneath it.
In this event, a Skilled Technician should test the appliance.
7.2 speCIal maIntenanCe
WARNING
Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE ACTION
Every 50 hours Check the pump hydraulic circuit.
Check the pump xing.
Every 100 hours Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.
CAUTION
The data in the table are indications.
8 dIsmantlInG and dIsposal
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current regulations