SNR S2995G-48TX-POE [6/12] Chapter 2 configure sequence
![SNR S2995G-48TX-POE [6/12] Chapter 2 configure sequence](/views2/1978545/page6/bg6.png)
Information Center Configuration Chapter 2 Configure Sequence
2-1
Chapter 2 Configure Sequence
1. Set the global enable of the information center
2. Set the output direction of the information center to enable
3. Set the log information prefix switch
4. Set the log information matching conditions
5. Configure the IP and facility of the log host
6. Configure the number of log files and access path
7. Configure to record user operation commands
8. Delete logs recorded by logbuffer or trapbuffer
9. View the area that supports storing files
10. Configure onekey collection
1. Set the global enable of the information center
2.
Set the output direction of the information center to enable
3.
Set the log information prefix switch
Command Description
Global configuration mode
info-center enable Set the global enable of the
information center
no info-center enable Set the global disable of the
information center
Command Description
Global configuration mode
info-center (co
nsole | logbuffer | monitor | trapbuffer)
output-enable
info-center (logfile <1-4> | loghost <1-8>) output-enable
(member <1-4> |)
Set the output direction of
the information center to
enable
no info-
center (console | logbuffer | monitor | trapbuffer)
output-enable
no info-center (logfile <1-4> | loghost <1-8>) output-enable
(member <1-16> |)
Set the output direction of
the information center to
disable
Command Description
Global configuration mode
info-center (console | logbuffer | monitor | trapbuffer) prefix Set the log information prefix
Содержание
- Basic concepts 1 1 1
- Chapter 1 overview 1 1 1
- Chapter 2 configure sequence 2 1 1
- Chapter 3 instructions 3 1 1
- Chapter 4 erratum 4 1 1
- Configure onekey collection 3 3 1
- Console output log 3 1 1
- Content 1
- Delete logs recorded by logbuffer or trapbuffer 3 3 1
- Information sources 1 1 1
- Logbuffer output log 3 1 1
- Logfile output log 3 2 1
- Loghost output log 3 2 1
- Monitor output log 3 1 1
- Output direction 1 1 1
- Record user operation commands 3 2 1
- Source information format 1 2 1
- Trapbuffer output log 3 1 1
- View the area that supports storing files 3 3 1
- Basic concepts 2
- Chapter 1 overview 2
- Information sources 2
- Output direction 2
- Priority 3
- Source information format 3
- Timestamp 4
- Content 5
- Digest 5
- Module 5
- Severity 5
- Sysname 5
- Chapter 2 configure sequence 6
- Chapter 3 instructions 9
- Console output log 9
- Logbuffer output log 9
- Monitor output log 9
- Trapbuffer output log 9
- Logfile output log 10
- Loghost output log 10
- Record user operation commands 10
- Configure onekey collection 11
- Delete logs recorded by logbuffer or trapbuffer 11
- View the area that supports storing files 11
- Chapter 4 erratum 12
Похожие устройства
- SNR S2995G-48TX-POE Техническое Описание
- SNR S5210G-24TX Техническое Описание
- SNR S5210G-24TX Руководство администратора
- SNR S5210G-24TX Руководство по эксплуатации
- SNR S5210G-24TX-UPS-R Техническое Описание
- SNR S5210G-24TX-UPS-R Руководство администратора
- SNR S5210G-24TX-UPS-R Руководство по эксплуатации
- SNR S5210X-8F Техническое Описание
- SNR S5210X-8F Руководство администратора
- SNR S5210X-8F Руководство по эксплуатации
- SNR S2982G-24TE-UPS Техническое Описание
- SNR S2982G-24TE-UPS Руководство по настройке
- SNR S5210G-24TX-UPS Техническое Описание
- SNR S5210G-24TX-UPS Руководство администратора
- SNR S5210G-24TX-UPS Руководство по эксплуатации
- SNR SNR-S7550Y-48C Техническое Описание
- SNR SNR-S7550Y-48C Руководство по Настройке
- SNR S2985G-24T-DC Техническое Описание
- SNR S2985G-24T-DC Руководство по настройке
- SNR S2962-24T-RPS Техническое Описание