SNR S2989G-24TX-POE — настройка и устранение неполадок EFM OAM для Ethernet [101/553]

Превью страниц Страница 101 / 553
SNR S2989G-24TX [101/553] Efm oam troubleshooting
2-37
Ethernet
1/0/1
Ethernet
1/0/1
S2989G-24TX Operation Manual Chapter 2 Layer 2 services
Configuration
2.8.3
EFM OAM Example
Example:
CE and PE devices with point-to-point link enable EFM OAM to monitor “the First Mile”
link performance. It will report the log information to network management system when
occurring fault event and use remote loopback function to detect the link in necessary
instance
CE
802.1ah OAMPDU
PE
Figure 2-13 Typical OAM application topology
Configuration procedure: (Omitting SNMP and Log configuration in the following)
Configuration on CE:
CE(config)#interface ethernet1/0/1
CE (config-if-ethernet1/0/1)#ethernet-oam mode passive
CE (config-if-ethernet1/0/1)#ethernet-oam
CE (config-if-ethernet1/0/1)#ethernet-oam remote-loopback supported
Other parameters use the default configuration.
Configuration on PE:
PE(config)#interface ethernet 1/0/1
PE (config-if-ethernet1/0/1)#ethernet-oam
Other parameters use the default configuration.
Execute the following command when using remote loopback.
PE(config-if-ethernet1/0/1)#ethernet-oam remote-loopback
Execute the following command to make one of OAM peers exiting OAM loopback after
complete detection.
PE(config-if-ethernet1/0/1)# no ethernet-oam remote-loopback
Execute the following command without supporting remote loopback.
CE(config-if-ethernet1/0/1)#no ethernet-oam remote-loopback supported
2.8.4
EFM OAM Troubleshooting
When using EFM OAM, it occurs the problem, please check whether the problem is
resulted by the following reasons:

Содержание

666

Узнайте, как настроить EFM OAM для мониторинга производительности Ethernet-соединений и устранить возможные неполадки. Подробные инструкции и примеры.