29
update. But the entire range of the parameter can still be accurately con-
trolled. In addition, if the actual range of the parameter is greater than 127,
MIDI control might be somewhat coarse. This is most noticeable with large
delays.
When MIDI is enabled, the PCM96 automatically sends MIDI messages
through the MIDI Out port for soft row parameters and preset loads when-
ever those actions are performed via the front panel controls.
SoFt RoW PARAMeteR/MIdI cc MAP
Soft Row Parameter MIDI CC
Parameter #1 CC 48
Parameter #2 CC 49
Parameter #3 CC 50
Parameter #4 CC 51
Parameter #5 CC 52
Parameter #6 CC 53
Parameter #7 CC 54
Parameter #8 CC 55
bANK/PReSet MAP
User Bank Type Presets MIDI Bank #
Internal
Mono
1 Mono User Presets 0-127 72
2 Mono User Presets 128-255 73
Stereo
1 Stereo User Presets 0-127 74
2 Stereo User Presets 128-255 75
System
1 System User Presets 0-127 76
2 System User Presets 128-255 77
Flash Card
(PCM96 and
PCM96 Surround
Only)
Mono
1 Mono User Presets 0-127 100
2 Mono User Presets 128-255 101
3 Mono User Presets 256-383 102
4 Mono User Presets 384-511 103
Stereo
1 Stereo User Presets 0-127 104
2 Stereo User Presets 128-255 105
3 Stereo User Presets 256-383 106
4 Stereo User Presets 384-511 107
System
1 System User Presets 0-127 108
2 System User Presets 128-255 109
3 System User Presets 256-383 110
4 System User Presets 384-511 111

Содержание