ELATION Design Wash 300E Руководство по эксплуатации онлайн [5/56] 758807
![ELATION Design Wash 300E Руководство по эксплуатации онлайн [5/56] 758807](/views2/1990522/page5/bg5.png)
Design Wash 300E™
©Elation Professional, Los Angeles Ca. 5 www.ElationLighting.com
Please do not discard the shipping carton in the trash. Please save for return shipping in the
event service is ever needed or recycle the container whenever possible.
WARRANTY REGISTRATION: The Design Wash 300E
™
carries a two year (730 days)
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid and
accompany a return authorization (R.A.) number. The R.A. number must be clearly written
on the outside of the return package. A brief description of the problem as well as the R.A.
number must also be written down on a piece of paper and included in the shipping
container. If the unit is under warranty, you must provide a copy of your proof of purchase
invoice. Items returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A. number by
contacting customer support at (323) 582-3322.
DISCHARGE LAMP WARNING: This fixture is fitted with a discharge
lamp, which is highly susceptible to damage if improperly handled.
Never touch the lamp with your bare hands, as the oil from your hands
will shorten lamp life. Also, never move the fixture until the lamps have
had ample time to cool. Remember, lamps are not covered under
warranty conditions.
UV RADIATION: This fixture emits intense UV radiation, which is harmful to the eyes and
skin. The intense luminance of the lamp can cause severe damage to the retina. Never
operate this fixture with the protective covers removed, these covers have been specially
designed to shield against UV radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the
lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce lamp
life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use a gas sealed in a
Содержание
- Design wash 300 1
- Elation professional 6122 s eastern ave 1
- Los angeles ca 90040 www elationlighting com 1
- Contents 3
- General information 4
- Safety instructions 7
- Features 9
- General guidelines 10
- Fixture overview 11
- Lamp installation instructions 12
- Been turned off 14
- Must wait approximately 15 minutes before you can attempt to strike the lamp once it has 14
- Please remember that a msr gold 300 2 lamp is not a hot restrike lamp therefore you 14
- Mounting and installation 15
- Understanding dmx 18
- Fixture menu 22
- Adjust the fixture s starting dmx address every device controlled by dmx has to have a 24
- Coming from the controller that is not meant specifically for the fixture because each 24
- Fixture is connected in a daisy chain fashion it is imperative to assign a proper and 24
- Function mode 24
- Is switched off memory is backed up and retain by an internal power source that should 24
- Last about five years for proper dmx addressing see section 10 page 34 of this user 24
- Manual 24
- Non destructive and will remain in the fixture s memory even when the power to the unit 24
- Properly the dmx address of a fixture is what allows it to communicate with a controller 24
- Properly the dmx addressing also allows the fixture to ignore any dmx information 24
- Set dmx address dmx address setting this function is used to set or 24
- Unique starting address the addressing feature is what allows dmx to function 24
- Unique starting dmx address to each and every fixture the dmx address is 24
- Value display display the dmx 512 value of each channel 24
- With this function you can display the dmx 512 value of each channel the display will 24
- Dmx addressing 34
- Operation 36
- Working with built in programs 38
- Dmx channel traits 41
- Dmx channel function and values 42
- Error codes 45
- Dimmer error 47
- Dimmer wheel error this message will appear after the reset of the fixture if the 47
- Located in the default position after the reset 47
- Magnetic indexing circuit malfunctions sensor failed or magnet missing or the 47
- Stepping motor is defective or its driving ic on the main pcb the dimmer wheel is not 47
- Cleaning and maintenance 48
- Year limited warranty 49
- Photometric data 51
- Dimensional drawings 52
- Circuit schematics 53
- Technical specifications 55
Похожие устройства
- DIALIGHTING LED Wash Wireless Руководство по эксплуатации
- DIALIGHTING LED Par Slim 12 Руководство по эксплуатации
- DIALIGHTING LED Par 64-177b Руководство по эксплуатации
- DIALIGHTING LED Par 24-10 Руководство по эксплуатации
- Marshall CODE212 Руководство по эксплуатации
- ELATION Design Spot 575 Руководство по эксплуатации
- Marshall 2536 and 2536A Руководство по эксплуатации
- Marshall 1960A and 1960B Руководство по эксплуатации
- Marshall Origin5 Руководство по эксплуатации
- Marshall DSL1C Руководство по эксплуатации
- Marshall DSL1H Руководство по эксплуатации
- Marshall DSL5 Руководство по эксплуатации
- Marshall DSL40 Руководство по эксплуатации
- Marshall DSL20C Руководство по эксплуатации
- Marshall JVM215 Руководство по эксплуатации
- Marshall CODE25 Руководство по эксплуатации
- Marshall CODE50 Руководство по эксплуатации
- Marshall MG10 Руководство по эксплуатации
- Marshall DSL20H Руководство по эксплуатации
- Marshall MG15R Руководство по эксплуатации