Planning aid
Laundry room appliances
J001062-R09
19.03.15
24
8
REFRESH-BUTLER – the textile care system
8.1
Installation
General condition
To prevent an impermissible rise in temperature and humidity, the room must be min. 20m
3
, or sufficiently large inlet and
outlet openings to an adjacent room or to the outside must be available (open windows, ventilation grilles or slots in the
door, ventilation systems). On the other hand there is the possibility of using the waste heat.
Normal bathroom extractor fans are not adequate for optimal room ventilation. They switch off with the light after a preset
after-running time.
Through the heat recovery of the heat pump dryer, heat dissipation is greatly reduced resulting in the imposition of far fewer de-
mands on the installation room. Heat pump dryers affect their environment like a heater blower with a heat output of approx.700W.
The appliance can be levelled by means of adjustable feet. The room must be kept free of dust and fluff.
Room climate and ventilation
Room temperature
Permissible room temperature: 5 °C to 30 °C
The room temperature should be kept as low as possible to ensure the economic running of the appliance. Critical is a room
temperature of 30 °C and over. This prolongs the duration of the programmes. High temperatures can also result in error
messages and impair the service life of the appliance.
Ventilation
As a general rule, rooms containing a textile care appliance must be ventilated as these produce some humidity. For each heat pump
dryer, the passage of exhaust and intake air must be guaranteed. EXHAUST AIR requires INTAKE AIR. At least the same amount of
air must be supplied to as is being extracted from the room. If the room is kept closed, the installation room volume must
be min. 20 m
3
.