Fulgor Milano SBQ 1000 G X [80/104] Cut out
![Fulgor Milano SBQ 1000 G X [80/104] Cut out](/views2/2005871/page80/bg50.png)
80 81
GB
505
177
ATTENTION
• The appliance requires adequate ventilation. An open area must be provided as shown
below. A ventilation grate can be applied, if desired. This ventilation surface allows air
to enter the compartment for the proper combustion of the gas and aspiration of the
combustion products. In the case of LPG, the gas is heavier than air; in the event of a leak
the vent allows the gas to leave the compartment. The air vent must be at least 700 mm x 25
mm and placed in a central position 135 mm below the mounting surface. (See drawing).
FRONT
MINIMUM DISTANCE FROM
WALL FOR COVER ROTATION
Cut out
Содержание
- English p.3
- Sommario p.3
- Italiano p.3
- Descrizione del prodotto p.4
- Barbecue integrato con coperchio sottile p.4
- Barbecue integrato coperchio alto p.5
- Componenti p.6
- Istruzioni importanti per la sicurezza p.8
- Responsabilita del costruttore p.11
- Montaggio del barbecue p.12
- Dettaglio h p.15
- Caratteristiche dei gas nei diversi paesi p.16
- Dettaglio a p.20
- En 10226 1 en 10226 2 en iso 228 1 p.23
- Informazioni di sicurezza in merito alle bombole del gas p.25
- Istruzioni di installazione e avvertenze p.26
- Attenzione p.26
- Fronte p.31
- Attenzione p.31
- Min 20 mm p.33
- Lunghezza max 1 5 metri p.33
- Distanza minima dalla parete 55mm p.33
- Attenzione p.33
- Allacciamento della bombola di gpl p.37
- Sinistro p.38
- Destro p.38
- Applicazione del coperchio sottile p.38
- Importante p.39
- Istruzioni d uso p.41
- Importante p.41
- Ricordarsi di chiudere sempre la valvola gas della bombola a fine utilizzo p.44
- L utilizzatore si ricordi di escludere il gas prima di chiudere il coperchio p.44
- Attenzione p.44
- Pulizia e cura p.45
- Avvertenza p.45
- Attenzione p.45
- Suggerimenti e informazioni p.49
- Manutenzione p.50
- Risoluzione dei problemi p.51
- Italiano p.53
- English p.53
- Contents p.53
- Product description p.54
- Integrated barbecue with thin cover p.54
- Integrated barbecue high cover p.55
- Components p.56
- Important safety instructions p.58
- Assembling the barbecue p.61
- Dettaglio h p.64
- Characteristics of gas in different countries p.65
- Dettaglio a p.69
- En 10226 1 en 10226 2 en iso 228 1 p.72
- Gas cylinder safety information p.74
- Installation instructions and warnings p.75
- Attention p.75
- Parete p.78
- Cut out p.80
- Attention p.80
- Distanza minima dalla parete 55mm p.82
- Attention p.82
- Minimum distance from the rear wall 55mm p.82
- Min 20 mm p.82
- Max length 1 metres p.82
- Lunghezza max 1 5 metri p.82
- Connection of the lpg cylinder p.86
- Application of the thin cover p.87
- Important p.88
- Detail a p.89
- Usage instructions p.90
- Important p.90
- Remember to shut off the gas before closing the cover p.93
- Remember to always close the valve of the gas cylinder after use p.93
- Attention p.93
- Warning p.94
- Cleaning and care p.94
- Attention p.94
- Suggestions and information p.98
- Maintenance p.99
- Detail g p.99
- Troubleshooting p.100
- Fulgor milano p.104
Похожие устройства
-
Fulgor Milano CPH 401 BQ TC XРуководство по эксплуатации -
Kitfort KT-1658Руководство по эксплуатации -
Kitfort KT-1657Руководство по эксплуатации -
Kitfort KT-1657Инструкция по эксплуатации -
Kitfort KT-1658Инструкция по эксплуатации -
Clatronic BQS 3444Инструкция по эксплуатации -
Miele CS1322 BGИнструкция по эксплуатации -
Steba vg 101 bbq table grillИнструкция по эксплуатации -
Bomann bq 1240 n schwarzИнструкция по эксплуатации -
Steba vg 120Инструкция по эксплуатации -
Steba vg 200Инструкция по эксплуатации -
Steba vg 250Инструкция по эксплуатации