Xiaomi Pocophone F1 128Gb+6Gb Dual LTE [81/118] Barometer

Xiaomi Pocophone F1 128Gb+6Gb Dual LTE [81/118] Barometer
TYPE_GYROSCOPE_UNCALIBRATED sensor.
[C-1-3] MUST be capable of measuring orientation changes up to 1,000 degrees per
second.
[C-1-4] MUST have a resolution of 12-bits or more and SHOULD have a resolution of 16-
bits or more.
[C-1-5] MUST be temperature compensated.
[C-1-6] MUST be calibrated and compensated while in use, and preserve the
compensation parameters between device reboots.
[C-1-7] MUST have a variance no greater than 1e-7 rad^2 / s^2 per Hz (variance per Hz, or
rad^2 / s). The variance is allowed to vary with the sampling rate, but MUST be
constrained by this value. In other words, if you measure the variance of the gyro at 1 Hz
sampling rate it SHOULD be no greater than 1e-7 rad^2/s^2.
[SR] Existing and new Android devices are STRONGLY RECOMMENDED to implement the
SENSOR_TYPE_GYROSCOPE_UNCALIBRATED sensor.
[SR] Calibration error is STRONGLY RECOMMENDED to be less than 0.01 rad/s when
device is stationary at room temperature.
SHOULD report events up to at least 200 Hz.
If device implementations include a gyroscope, an accelerometer sensor and a magnetometer
sensor, they:
[C-2-1] MUST implement a TYPE_ROTATION_VECTOR composite sensor.
If device implementations include a gyroscope and a accelerometer sensor, they:
[C-3-1] MUST implement the TYPE_GRAVITY and TYPE_LINEAR_ACCELERATION
composite sensors.
[SR] Existing and new Android devices are STRONGLY RECOMMENDED to implement the
TYPE_GAME_ROTATION_VECTOR sensor.
SHOULD implement the TYPE_GAME_ROTATION_VECTOR composite sensor.
7.3.5. Barometer
Device implementations SHOULD include a barometer (ambient air pressure sensor).
If device implementations include a barometer, they:
[C-1-1] MUST implement and report TYPE_PRESSURE sensor.
[C-1-2] MUST be able to deliver events at 5 Hz or greater.
[C-1-3] MUST be temperature compensated.
[SR] STRONGLY RECOMMENDED to be able to report pressure measurements in the range
300hPa to 1100hPa.
SHOULD have an absolute accuracy of 1hPa.
SHOULD have a relative accuracy of 0.12hPa over 20hPa range (equivalent to ~1m
accuracy over ~200m change at sea level).
7.3.6. Thermometer
Device implementations: MAY include an ambient thermometer (temperature sensor). MAY but
SHOULD NOT include a CPU temperature sensor.
If device implementations include an ambient thermometer (temperature sensor), they:
Page 81 of 118