Faber HIGH-LIGHT WH MATT A91 [3/160] Safety information

Faber HIGH-LIGHT WH MATT A91 [3/160] Safety information
3
1. SAFETY INFORMATION
For your safety and correct
operation of the appliance, read
this manual carefully before instal-
lation and use. Always keep these
instructions with the appliance even
if you move or sell it. Users must
fully know the operation and safe-
ty features of the appliance.
The wire connection has to
be done by specialized
technician.
The manufacturer will not be
held liable for any damages
resulting from incorrect or im-
proper installation.
The minimum safety distance
between the cooker top and
the extractor hood is 650 mm
(some models can be installed
at a lower height, please refer
to the paragraphs on working
dimensions and installation).
If the instructions for installa-
tion for the gas hob specify a
greater distance, this must be
respected.
Check that the mains voltage
corresponds to that indicated
ontheratingplatexedtothe
inside of the hood.
Means for disconnection must
be incorporated in the xed
wiring in accordance with the
wiring rules.
For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
Connect the extractor to the
exhaustuethroughapipeof
minimum diameter 120 mm.
Therouteoftheuemustbe
as short as possible.
Regulations concerning the dis-
chargeofairhavetobefullled.
Do not connect the extractor
hood to exhaust ducts carrying
combustionfumes(boilers,re-
places, etc.).
If the extractor is used in conjunc-
tion with non-electrical applianc-
es (e.g. gas burning appliances),
asufcientdegreeofaeration
must be guaranteed in the room
inordertopreventthebackow
of exhaust gas. When the cooker
hood is used in conjunction with
appliances supplied with energy
other than electric, the negative
pressure in the room must not
exceed 0,04 mbar to prevent
fumes being drawn back into the
room by the cooker hood.
The air must not be discharged
intoauethatisusedforex-
hausting fumes from appliances
burning gas or other fuels.
If the supply cord is damaged, it
must be replaced from the man-
ufacturer or its service agent.
Connect the plug to a socket
complying with current regula-
tions, located in an accessible
place.
With regards to the technical
and safety measures to be
adopted for fume discharging
it is important to closely follow
EN