Checking for gas leaks
1. Soapy water method. Using a soft brush, apply
soapy water or neutral liquid detergent to the con-
nections of the internal and external unit to check
the pipeline connections for leaks. The appearance
of bubbles indicates the presence of a leak.
2. Leak sensor. The presence of leaks can be checked
using a special sensor.
Test turn-on
After completing the gas leak check and electrical safety
check, the test activation of the unit should be performed.
The duration of the test activation should be more
than 30 minutes.
Make sure that the electrical wires are proper-
ly attached and the pipelines are properly con-
nected.
Make sure that the service valves of the liquid and
gas system are fully open.
Checking the operational capability
of all functions
1. Turn on the unit by pressing the «ON/OFF» button
(22) on the remote controller.
2. Using the «MODE» button (23), choose the operating
modes of the unit: (33) cooling « », (36) heating
« », (32) automatic mode « », (35) ventilation « »
to check the operation of all functions.