Селективный металлодетектор «Сигнум MFT» 7272М. Руководство по эксплуатации.
degrees. If you encounter this problem then perform the ground balance procedure
as follows.
Find a clean patch of ground with a width of 60 centimeters. Switch to manual ground
balance and making short horizontal search sweeps with a width of 50cm at a height 3-5cm
above the ground, you will see a straight line on the ground the screen (if the line jumps,
then there is metal present). In this case, if the balance is wrong, you will hear a buzz from
the soil and the soil line on the on the screen will not be horizontal.
Press and until the line is horizontal and the buzz disappears.
Your device is fine-tuned to the ground.
For a small increase in the depth of the identification of large silver and copper
coins (kettles, basins and other large pieces of highly conductive metals) it is possible, after
performing automatic ground balancing, to enter the manual balance mode and set the GB
point from -1 to -2 from the automatic GB reference point.
Care should be taken when setting the ground balance point either negative or
positive. When set negative it increases the possibility of receiving false positive responses
when bumping the coil on vegetation or the ground. When set positive you risk the chance of
losing sensitivity to large silver or copper coins that will either become “invisible” or ID as
iron.
In the event that a “clean” patch of ground is not found you can excavate a small
amount of local soil (1-1.5 kg), removing all metal objects, and place in a bag for
convenience. Now lean the detector with the coil facing up against a bush or tree with the
coil at least 40-50cm off the ground. With the bag of soil in hand you can now and press
the GB button
and count 1,2,3. Then smooth and slow, (starting from a distance of
30-40 cm) present the soil to coil. (As if doing auto balance on the ground in the normal
mode, but now you are moving the soil to the coil instead of vice versa)
Placing the excavated soil on the ground is not desirable. Since you were not able
to perform a ground balance previously, due to the presence of metal in ground, placing the
bag of soil on the ground may cause an incorrect ground balance.
Attention! If the signal from the ground is too small (such as quartz sand) and the
auto balance cannot be performed then the balancing procedure can be
performed either by using a piece of ferrite or a piece of red brick. These can be
placed on the ground and the auto balance procedure performed. In principle,
using the procedure for balancing for “an air test” will also work and you may set
the balance point 1 or 2 degrees negative if you are searching for large objects.
Sharp temperature changes on the search coil may impact balancing accuracy,
the balance may shift and become incorrect with such changes. That is why, if you take the
device from a heated car and start working in a low temperature conditions (early spring, late
fall), rebalance one or two times while the coil adapts to the ambient temperature.
In case of large temperature drops of more, than 15°С (compared to a normal air
temp of 20C), we recommend that you perform electronic module and search coil
Содержание
- Discriminating metal detector 1
- Instruction manual 1
- Signum mft 1
- Contents 3
- General description 4
- General information 4
- Package contents 5
- Technical specifications 5
- Getting started 6
- Power supply 6
- Controls and connections 7
- Display screen 9
- St sensitivity rt sensitivity volume 9
- Warning setting of the st sensitivity above 11 and especially 14 can lead to a significant increase in the amount of false positives from the soil in high salinity or when bumping the search coil 9
- Ground balance 10
- Make the soil invisible to the instrument i e exclude false signals from the ground where there is no target 10
- Successiv 12
- Discrimination search mode and setup 14
- Search mode all metal 15
- Dynamic and static modes 16
- Mode economy 17
- Mode s algorithm 17
- Mode turbo 17
- Multi frequency 18
- Parameter menu 19
- Search options 19
- Accumulation 20
- Attention the algorithm is turned off automatically in the program 20
- Backlight 20
- Display settings 20
- Mm1 and mm2 20
- Shift frequency 5 the central frequency of the device 5 20
- 2 1 4 1 7 21
- Real time before the threshold short tone 21
- Real time multifrequency 21
- Sound settings 21
- Additional menu add menu 22
- Menu options 22
- Other settings 23
- Tone settings rt 23
- Tone settings st 23
- User programs 23
- Always go back to them to perform this you must first turn on the device while at the 24
- Factory default values for all parameters are stored in memory and the user can 24
- However one should pay attention to two points unless absolutely necessary do not place a high value for the backlight setting doing so may reduce the operation time with one set of batteries it is also not recommended to set too high a level for the parameter duration st when working in trashy areas for a clearer separation of closely spaced targets 24
- Program 2 designed to search in trashy areas has a good response but slightly inferior in sensitivity program 3 is the main program of research combining the best combinations for a comfortable search with near maximum sensitivity program 4 for when you want to search at slightly greater depths however it is worth remembering that it reduces the comfort of searching identifying deteriorating properties of the device as well as the time from one set of batteries is reduced by 2 3 times remember that the default settings are not an absolute but offered only as a starting point to assist your search experiment and we hope that in the near future you will make your own comfortable and effective progra 24
- Same time holding down the button and hold it until the end of the melody same time holding down the button and hold it until the end of the melody program 1 is designed for easy and comfortable search of shallow objects 24
- Settings backlight contrast and cont ct directly with the search capabilities of 24
- The device are not affected and can be chosen based on the preferences of the particular user 24
- Using the hodograph for identification 25
- Replacing the coil 26
- Search and identification methods 26
- Normal operating mode 28
- S mode algorithm 28
- Large eddy current loops 30
- Searching for metal objects with 30
- Examples of some common target 32
- Us 5 cent nickel 32
- Warranty information 33
Похожие устройства
- Ака СИГНУМ MFT/MFD модель 7272М версия 2.0х Руководство пользователя
- Ака Intronik STF Руководство пользователя ч2
- Ака Intronik STF Руководство пользователя
- Ака Intronik STF Краткая инструкция по эксплуатации
- Ака Разгрузка Руководство пользователя
- Ака Сорекс Pro 7281 Руководство пользователя
- Ака УНИСКАН модель 7215М Руководство пользователя
- ACV BOILER TKAN 300 По Монтажу, эксплуатации и обслуживанию котла
- Kuppersberg WM 490 W Инструкция по эксплуатации
- Kuppersberg WM 410 W Инструкция по эксплуатации
- Kuppersberg WID 56149 W Инструкция по эксплуатации
- Kuppersberg WDM 560 Инструкция по эксплуатации
- Kuppersberg WM 581 W Инструкция по эксплуатации
- Kuppersberg WM 520 W Инструкция по эксплуатации
- Kuppersberg WM 411 W Инструкция по эксплуатации
- Kuppersberg RFWI 1890 SIG Инструкция по эксплуатации
- Kuppersberg RFFI 184 WG Инструкция по эксплуатации
- Kuppersberg RFFI 184 BG Инструкция по эксплуатации
- Kuppersberg NMFV 18591 DX Инструкция по эксплуатации
- Kuppersberg NFFD 183 BKG Инструкция по эксплуатации