TECHNICAL PASSPORT ENGLISH
Built-in hob
Positioning
 This appliance isn’t connected to
any scavenging devices of combustion
products.
 The appliance can only be in-
stalled and operate in permanently
ventilated rooms according to the local
regulations in force.
 The natural ow of air must be
direct through permanent holes made
in the walls of the room to be ventilated
leading to the outside, or through single
or collective branched ventilation ducts.
 The ventilation openings must
have a effective cross-section of at least
100 cm
2
and must be protected against
accidental blocking (protection with
metal grills or grids). For appliances
without safety valve on the hob, the
opening section is doubled with a mini-
mum of 200 cm
2
.
 There may also be an indirect
ow of air from rooms next to that
where the appliance is installed, as long
as these rooms have direct ventilation,
there is no re risk in these rooms and
they are not bedrooms.
 The  ow of air between adjacent
room and the room where it is installed
must be free through permanent open-
ings (which may be obtained by making
the gap between door and  oor larger).
 In the room where it is installed
there must be a system for leading the
combustion fumes to the outside. This
may be with a hood or an electric fan
which switches on when the appliance
is switched on.
Gas connection
 The appliance must be connected
to the gas supply or the cylinder accor-
ding to the speci cations of the stan-
dards in force and after checking that it
is adjusted for the type of gas available.
 The appliance is set up to oper-
ate with the gas speci ed on the cali-
bration label placed both on the pack-
aging and on the back of the appliance.
 When the type of gas available
does not correspond to that for which
the appliance is set up, replace the cor-
responding injectors (provided), being
careful to put on the new calibration la-
bel (provided) and remove the old one.
 To perform these operations the
quali ed installer will follow the indi-
cations given in the Adaptation to the
various types of gas” section.
 For safety operation make sure
that the supply pressure respects the
values given in the “Table of burner and
injector characteristics”.
 If the appliance is supplied with
liquid cylinder gas, make sure that the
cylin- der pressure regulator conforms
to the local regulations in force.
 The appliance must be connect-
ed to the gas system by a rigid metal
pipe (copper or steel) or continuous
wall stainless steel exible hose in such
INSTALLING THE HOB